Trane Axiom GET024-036 Installation, Operation And Maintenance Manual page 6

Water source heat pump high efficiency vertical stack
Table of Contents

Advertisement

Model Number Descriptions
Digit 34, 35, 36: Riser Length
000 = No riser
096 = 96-inch riser length
097 = 97-inch riser length
098 = 98-inch riser length
099 = 99-inch riser length
100 = 100-inch riser length
101 = 101-inch riser length
102 = 102-inch riser length
103 = 103-inch riser length
104 = 104-inch riser length
105 = 105-inch riser length
106 = 106-inch riser length
107 = 107-inch riser length
108 = 108-inch riser length
109 = 109-inch riser length
110 = 110-inch riser length
111 = 111-inch riser length
112 = 112-inch riser length
113 = 113-inch riser length
114 = 114-inch riser length
115 = 115-inch riser length
116 = 116-inch riser length
117 = 117-inch riser length
118 = 118-inch riser length
119 = 119-inch riser length
120 = 120-inch riser length
Vertical High-Rise Chassis
WSHP
Digits 1-3: Unit Configuration
GET = High efficiency vertical high rise
heat pump
Digit 4: Development Sequence
E
=
R-410A
Digits 5-7: Nominal Size (Tons)
009 = 0.75 Tons
012 = 1 Tons
015 = 1.25 Tons
018 = 1.5 Tons
024 = 2 Tons
036 = 3 Tons
Digit 8: Voltage (Volts/Hz/Phase)
1 = 208/60/1
2 = 230/60/1
7 = 265/60/1
Digit 9: Heat Exchanger
1 = Copper water coil
2 = Cupro-nickel water coil
3 = Copper water coil with isolation
valve and low flow control
4 = Cupro- nickel water coil with isolation
valve and low flow control
5 = Copper water coil with isolation 
valve and high flow control
6 = Cupro-nickel water coil with isolation
valve and high flow control
1
20°F Freezestat is typically used in a geothermal application. 35°F Freezestat is typically used in a boiler/tower application.
6
Digit 10: Current Design Sequence
Digit 11: Refrigeration Circuit
0 = Heating and cooling circuit
Digit 12: Blower Configuration
1 = Free discharge (factory wire low
speed) - PSC motor
2 = Ducted (factory wire hi speed) - PSC
motor
3 = Free discharge with 1-inch flange - 
PSC motor
4 = Free discharge with 3-inch flange - 
PSC motor
5 = ECM without flange
6 = ECM with 1-inch flange
7 = ECM with 3-inch flange
8 = Chassis only/no motor (ECM control)
9 = Chassis only/no motor (PSC control)
Digit 13: Freeze Protection
A = 20° Freezestat (For Glycol loop)
B = 35° Freezestat (For Water loop)
Digit 14: Open Digit
0 = Open
Digit 15: Supply Air Arrangement
0 = Field cut supply air arrangement
1 = Back and front supply air
arrangement
2 = Back and left supply air
arrangement
3 = Back and right supply air
arrangement
4 = Front and left supply air
arrangement
5 = Front and right supply air
arrangement
6 = Left and right supply air
arrangement
7 = Back, front and right supply air
arrangement
8 = Back, front and left supply air
arrangement
9 = Front, right and left supply air
arrangement
B = Back supply air arrangement
L = Left supply air arrangement
R = Right supply air arrangement
T = Top supply air arrangement
F = Front supply air arrangement
Digit 16: Return Air Arrangement
0 = No door (chassis only)
1 = Flush with wall, hinged return air
door
3 = Hinged return air door, tamper resistant
(HEX)
4 = Hinged return air door, with key lock
Digit 17: Control Types
0 = Basic controls for WPRD retrofit
chassis
C = Tracer® ZN510 controls
D = Deluxe 24V controls
H = UC400-B
J = UC400-B with Air-Fi® Wireless
Communications
Digit 18: Thermostat Sensor
Location
0 = Wall mounted location
Digit 19: Fault Sensors
0= No fault sensors
1 = Condensate overflow sensor
2 = Filter maintenance timer
3 = Condensate overflow and filter
maintenance timer
1
Digit 20: Temperature Sensor
0 = No additional temperature sensors
1 = Entering water sensor
Digit 21-22: Open Digits
Digit 23: Unit Mounted Disconnect
0 = No unit mounted switch
C = ON/OFF switch
D = ON/OFF switch with fuses
Digit 24: Filter Type
1 = 1-inch Throwaway filter
Digit 25: Acoustic Arrangement
0 = Enhanced sound attenuation
1 = Deluxe sound attenuation
Digit 26: Factory Configuration
2 = R-410A chassis
R = WPRD retrofit chassis
Digit 27: Paint Color
9 = Light white finish
Digit 28: Outside Air Option
0 = No outside air
Digit 29: Piping Arrangement
B = Back riser location
L = Left hand riser location
R = Right hand riser location
Digit 30: Riser Type
0 = No riser (chassis only)
Digit 31: Supply Riser
0 = No riser (chassis only)
Digit 32: Return Riser
0 = No riser (chassis only)
Digit 33: Condensate Riser
0 = No riser (chassis only)
Digit 34, 35, 36: Riser Length
000 = No riser (chassis only)
WSHP-SVX10H-EN

Advertisement

Table of Contents
loading

Table of Contents