Siemens SIMATIC NET SCALANCE X-100 Series Operating Instructions Manual page 57

Industrial ethernet
Table of Contents

Advertisement

Table 6- 5
Permitted cable lengths (fiber-optic)
Device type
1 - 50 m
SCALANCE
980/1000
plastic optical
fiber (POF)
X104-2
X106-1
X108
X108PoE
X112-2
X116
X124
Table 6- 6
Aging time / learnable MAC addresses / MTBF
Device type
Aging time
SCALANCE
X104-2
30 seconds
X106-1
30 seconds
X108
30 seconds
X108PoE
30 seconds
X112-2
30 seconds
X116
30 seconds
X124
30 seconds
Table 6- 7
Permitted environmental conditions / EMC
Device type
Operating temperature
SCALANCE
X104-2
-10 to +60° C
X106-1
-10 to +60° C
X108
-20 to +70° C
SCALANCE X-100
Operating Instructions, 04, A2B00060666D
1 - 100 m
200/230 polymer
cladded fiber (PCF)
6 dB max. permitted FO
cable attenuation with
3 dB link power margin
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Storage/transport
temperature
-40 to +80° C
-40 to +80° C
-40 to +80° C
0 - 3,000 m
glass FOC
62.5/125 µm or
50/125 µm glass fiber;
≤ 1 dB/km at 1300 nm;
≥ 600 MHz
km;
x
6 dB max. permitted FO
cable attenuation with 3
dB link power margin
+
+
-
-
+
-
-
learnable MAC addresses
2048
2048
2048
2048
8096
8096
8096
Relative
humidity in
operation
‹ 95 %
(no
condensation)
‹ 95 %
(no
condensation)
‹ 95 %
(no
condensation)
Technical specifications
6.1 Technical specifications
0 - 26000 m
glass FOC
10/125 µm single mode fiber;
0.5 dB/km at 1300 nm;
13 dB max. permitted FO
cable attenuation with 2 dB
link power margin
-
-
-
-
-
-
-
MTBF
134.87 years
136.65 years
139.83 years
61.64 years
61.3 years
61.3 years
49.3 years
Operating altitude at max.
xx°C ambient temperature
2000 m at max. 56° C
3000 m at max. 50° C
2000 m at max. 56° C
3000 m at max. 50° C
2000 m at max. 56° C
3000 m at max. 50° C
57

Advertisement

Table of Contents
loading

Table of Contents