Installation, connecting up, sources of problems
4.1 Assembly
Uninstalling
To remove Industrial Ethernet switches of the SCALANCE X-100 product line from the
SIMATIC S7-300 standard rail:
1. First disconnect all connected cables.
2. Loosen the device screws on the underside of the S7 standard rail and lift the device
4.1.3

Wall mounting

Wall mounting
1. For wall mounting, use suitable mounting fittings for the wall
2. Connect the electrical cable connecting cables.
3. Fit the connectors for the signaling contact.
4. Insert the terminal blocks into the sockets on the device.
For more exact dimensions, please refer to the section "Dimension drawings".
Note
The wall mounting must be capable of supporting at least four times the weight of the device.
44
away from the rail.
(for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws
3.5 mm diameter and 40 mm long).
SCALANCE X-100
Operating Instructions, 04, A2B00060666D