Product properties
3.8 SCALANCE X112-2
Since the full duplex mode and the transmission rate cannot be modified for optical
transmission, autonegotiation cannot be selected.
Transmission medium
Data transmission is over multimode fiber-optic cable (FOC). The wavelength is 1310 nm.
Multimode fiber-optic cables are used with a core of 50 or 62.5 µm; the light source is an
LED.
The outer diameter of the FOC is 125 µm.
Transmission range
The maximum transmission range (segment length) is 3 km.
Connectors
The cables are connected over BFOC sockets.