Seeley Braemar SBHVD1S Series Owner's Manual
Seeley Braemar SBHVD1S Series Owner's Manual

Seeley Braemar SBHVD1S Series Owner's Manual

Cassette inverter

Advertisement

OWNER'S MANUAL
CASSETTE INVERTER
HOUR
ONOFF
(English) (SBHVD1S SERIES)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Braemar SBHVD1S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Seeley Braemar SBHVD1S Series

  • Page 1 OWNER’S MANUAL CASSETTE INVERTER HOUR ONOFF (English) (SBHVD1S SERIES)
  • Page 2 IMPORTANT IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is As with any product that has moving parts or is subject to wear and tear, it is that you maintain your air conditioner and have it regularly VERY IMPORTANT that you maintain your air conditioner and have it regularly...
  • Page 3: Table Of Contents

    ERROR DISPLAY..................9-10 ERROR DISPLAY..................9-10 MAINTENANCE & SERVICE...............11-12 MAINTENANCE & SERVICE...............11-12 MAINTENANCE SCHEDULE ................13 MAINTENANCE SCHEDULE ................13 OPERATION TIPS.....................14 OPERATION TIPS.....................14 TROUBLESHOOTING ..................15 TROUBLESHOOTING ..................15 WARRANTY & SERVICE..................16 WARRANTY & SERVICE..................16 SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 4: Main Components

    MAIN COMPONENTS INDOOR UNIT receiver “88" display Auto button window 1. Drainage device 2. Condensate tube 3. Air vane 4. Connection pipe timer power Test 5. Display panel indicator indicator button 6. Remote control 7. Wired Controller (optional) 8. Condensate tube Air inlet 9.
  • Page 5: Introduction & Safety

    SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 6: Operation

    OPERATION Your Braemar Cassette Air This is a generic remote NOTE: Conditioning Unit has been designed control, used for multiple types of air and built with reliable, quality conditioner. Not all functions shown components. To ensure many years of on the remote control may be trouble free, dependable service operational for this unit.
  • Page 7: Controller Layout

    Child lock Light Light Swing Up/Down Swing Up/Down Temp. display type Temp. display type :Set temp. :Set temp. :Indoor ambient temp. :Indoor ambient temp. :Outdoor ambient temp. :Outdoor ambient temp. SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 8: On/Off

    OPERATION cont. ON / OFF FAN SPEED Press to turn the power on or off. Press the FAN button to toggle SLEEP function will be cancelled when between AUTO, Low, Medium and power is turned off. High speed. AUTO MODE Press to toggle between AUTO, AUTO fan speed is default on power COOL, DRY, FAN and HEAT modes.
  • Page 9: Timer Settings

    Holding these buttons unit to stop. Holding these buttons down will produce rapid adjustment. down will produce rapid adjustment. SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 10: Turbo

    OPERATION cont. OPERATION cont. OPERATION cont. LOCK LOCK TURBO TURBO LOCK TURBO The remote controller can be locked The remote controller can be locked The remote controller can be locked When the unit is first turned on in When the unit is first turned on in When the unit is first turned on in from inadvertent button operation.
  • Page 11: Error Display

    Condenser temperature sensor error Outdoor ambient temperature sensor error Discharge temperature sensor error Temperature sensor error of wired controller Outdoor memory chip error Electric box sensor error Compressor overload protection Overloading IPM protection DC fan motor error SEELEY INTERNATIONAL - OWNER’S MANUAL...
  • Page 12 OPERATION cont. ERROR DISPLAY cont. Number Error Code Error Description Drive desynchronizing protection Pfc protection Activation failure Compressor phase sequence protection Compressor stalling protection Power protection Indoor and outdoor mismatch 4-way valve direction changing protection Drive reset protection Over-current protection Communication error between main control and drive Drive module sensor error Drive module over temperature protection...
  • Page 13: Maintenance & Service

    Remove the screws and set aside for Remove the screws and set aside for reinsertion later. reinsertion later. SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 14 MAINTENANCE & SERVICE cont. MAINTENANCE & SERVICE cont. MAINTENANCE & SERVICE cont. MAINTENANCE & SERVICE cont. INDOOR UNIT (REFER PAGE 2) INDOOR COIL (REFER PAGE 2) INDOOR COIL (REFER PAGE 2) INDOOR COIL (REFER PAGE 2) Ensure drain connections are checked Ensure drain connections are checked Ensure drain connections are checked Ensure drain connections are checked...
  • Page 15: Maintenance Schedule

    Schedule, and as indicated elsewhere in this Manual. and frequency set out in the Schedule, and as indicated elsewhere in this Manual. SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 16: Operation Tips

    OPERATION TIPS OPERATION TIPS The following events may occur during normal operation: The following events may occur during normal operation: 1. Protection of the air conditioner. 1. Protection of the air conditioner. Compressor protection Compressor protection • The compressor cannot restart for 3 minutes after it stops. •...
  • Page 17: Troubleshooting

    Electricity by the Electricity Supplier. Supplier. SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 18: Warranty & Service

    NOTE: NOTE: Seeley International strives for continuous product improvements, therefore specifications are subject Seeley International strives for continuous product improvements, therefore specifications are subject to change without notice. Unit colour may vary slightly from that depicted in this booklet.
  • Page 19 NOTE NOTE SEELEY INTERNATIONAL - OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 20 It is the policy of Seeley International to introduce continuous product improvements. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. Warranty Service Refrigerated Cooling 1300 526 477 seeleyinternational.com...

Table of Contents