7.4.2. Replacing the activated carbon cassette

Open the service door of the activated carbon housing (see chapter 2.1).
Lower the lifting device (A) by turning the clamping screw (B). Therefore, use the hexagon key
that is located on the right of the clamping screw.
Carefully pull the entire filter pack, incl. the activated carbon cassette (see chapter 2.1), out of
the housing. (If a spacer frame is mounted in addition, it must be carefully removed as well.)
Replace the activated carbon cassette.
Only use TEKA spare filters. Otherwise the proper functioning of the unit is
not guaranteed.Push the filter pack back into the filter housing. Make sure that the filter
elements are inserted in the correct order.
Elevate the lifting device by turning the clamping screw so that the entire filter pack is pressed
tightly against the above housing.
Close the service door.

8. Dismantling / Disposal

Only authorised personnel may disassemble the machine.
WARNING
Dangers arising from electricity.
Before the dismantling of the machine it has to be disconnected from the power supply and
all supply lines.
CAUTION
Whirling up dust is possible due to the deposited dust.
During all work a suitable respiratory protection and protective clothing have to be worn.
The operator is obliged to store and dispose of the collected dust in accordance with national or
regional regulations.