TECHNICAL DATA: ..........................8 Thank you for purchasing this Goodway AQ-V-3M. We appreciate your business and look forward to serving you in the future. As with all Goodway products, you can be assured that the finest quality components and workmanship have gone into this machine.
Do not use the machine if it has a damaged cord or plug. Other than the 3 filters, there are no user serviceable components in the Goodway AQ-V-3M. Only trained technicians should attempt to make internal repairs on this equipment.
16. Do not use unit with combustible fluids or where combustible fluids or fumes may be present. 17. The Goodway AQ-V-3M is designed for US standard 115 volt, 60 Hz AC. Volt. Always check the specifications on the equipment before connecting electrical power to equipment.
To test the AQ-V-3M, be sure all filters are in place and the top is closed and latched in place, and the switch is in the off position. Connect the 12 gauge x 50 foot power cord to an outlet.
The thermal overload sensor will reset. • If the motor has cooled down and didn’t automatically reset. Remove the switch plate (S02 square drive), and press the red reset button on the motor. See below for images. AQ-V-3M...
Page 7
TO RESET THE THERMAL OVERLOAD, FOLLOW THE INSTRUCTIONS BELOW: Remove the 6 square drive screws on the front panel. Press the red button located on the front side of the electrical box on the motor. AQ-V-3M...
Need help?
Do you have a question about the AQ-V-3M and is the answer not in the manual?
Questions and answers