  • Page 1 CTV-1501 TowerVac® Cooling Tower Vacuum Operating and Maintenance Instructions Read before operating.
  • Page 2: Table Of Contents

    NOTES ..............................11 Thank you for purchasing this Goodway Cooling Tower Vacuum. We appreciate your business and look forward to serving you in the future. As with all Goodway products, you can be assured that the finest quality components and workmanship have gone into this machine.
  • Page 3: General

    3/16” (4,76 mm). When the TowerVac® is used by itself, the removed debris can be flushed down roof or storm drains. When it is used with Goodway Technologies’ CTV-F2 filtration system the water can be returned to the cooling tower.
  • Page 4: Special Safety Points

    GROUND FAULT CIRCUIT INTERRUPTER PROTECTION The CTV-1501 is provided with a Ground Fault Circuit Interrupter (GFCI) built into the power supply cord. This device provides additional protection from the risk of electrical shock. Should replacement of the cord or plug become necessary, use only identical replacement parts that include GFCI protection.
  • Page 5: Extension Cords

    If foam or liquid escapes from appliance, switch off immediately ELECTRIC MOTOR The CTV-1501 utilizes an electric motor equipped with thermal overload protection. Should the motor overheat, the thermal overload will cut off power to the motor. The overload is automatically reset when the motor cools down sufficiently.
  • Page 6 Outlet valve should be closed. Make sure the power switch is turned off. Plug the unit into a properly grounded outlet and reset the GFCI. Outlet Valve Prime Valve Outlet Fitting Prime Inlet Power Switch Inlet Fitting CTV-1501 0220...
  • Page 7: Priming / Operation

    For longer than 15 minutes, close the inlet valve, turn off the power switch and relocate the machine or change tool. Repeat the priming process described above. CTV-1501 0220...
  • Page 8: Maintenance

    Periodically check the hoses, connections and other components for wear and replace as necessary. COLD WEATHER STORAGE: Should the CTV-1501 need to be stored where freezing conditions may exist, turn the machine on and open the outlet valve to drain the water from the machine. TROUBLESHOOTING...
  • Page 9: Ctv-1501 Assembley Drawing

    CTV-1501 ASSEMBLY DRAWING AMT PUMP INLET CTV-1501 0220...
  • Page 10: Ctv-1501 Wiring Diagram

    CTV-1501 WIRING DIAGRAM TECHNICAL DATA Motor Power: 1½ HP (1kW) Input Power: Standard: 15 amps, 115V, 60 Hz AC Optional: 15 amps, 115V, 50 Hz AC Optional: 7.5 amps, 230V, 60 Hz Optional: 7.5 amps, 230V, 50 Hz Power Supply Cord:...
  • Page 11: Notes

    NOTES CTV-1501 0220...
  • Page 12 Visit: www.goodway.com P/N: MNL-CTV-1501 ©Copyright 2020 Goodway Technologies Corp., Stamford, CT USA Effective date February 28, 2020 Goodway is a Trademark of Crossford International. Goodway reserves the right to improve products; contact the factory for the latest configuration and uses.