Page 1
Temperature range (see material temperature range on page 4) 0 - 158 ºF (0 - 70º C) R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 2
Fluids not suitable for the pump can cause damage to the pump unit and involve risk of serious personal injury. • Always consult Samson Corporation if you have any questions about the compatibility within the fluids and the pump materials, including elastomers.
Page 3
Description Code Description Standard Threaded air outlet NPSM Diaphragm rupture detector Stroke sensor Pressure relief valve R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 5
94,51 mm 1" 210 mm 3/8" NPSM 8,5" 7,44" 8,94" 6,89" 6,06" 0,35" 7,24" 8,27" 3,72" 8,27" R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 6
When installing the pump in its place, use brackets to secure its base. • Fasten all bolts with the torques contained in this manual. (See page 20). 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 7
Submerged: All pumps DF-100 can be immersed in fluids. It is important to verify that all components that are in contact with the fluid are chemically compatible. In this case, air exhaust and fluid must be carried by hoses (optional air connection).
Page 8
If the valve of the standby pump is open, the discharge pressure pump operating side can go to the backup pump, causing damage. 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 9
• DF-100 pumps do not exceed a nominal noise level of 70 dB. It is recommended to use hearing protection when working near a diaphragm pump. Noise can be significantly reduced using a remote exhaust using a hose attached to the appropriate port in the air exhaust (optional connection not supplied with the pump).
Page 10
(such as gases in the air or the GROUND WIRE type of the surrounding facilities) static electricity can cause fire or electric shock. 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 11
Any change or modification is made at your own risk and it will invalidate the approval for the Atex pump atmospheres (Ex). R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 12
Pump parts DF100 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 13
* Externally controlled models fits the same pump body than normal directional valve. * Externally controlled models fits the same valve caps than normal directional valve. R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 14
Standard air outlet XXX-XX-XX-XB-X 558301 Driven air exhaust Externally controlled directional valve (no EXX-XX-XX-XX-X ------------ sensor available) 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 15
Cause Recommended measure The diaphragm is damaged. Remove and inspect the pump and replace the diaphragm. R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 16
No start-up and is leaking air without cycles. Cause Recommended measure Stiff air sensors. Change air sensor. Wear directional valve. Replace. 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 17
Repair and maintenance procedures (DIRECTIONAL VALVE) There are several models of directional valves mounted on diaphragm pumps DF-100. Externally controlled directional valve, directional valve with remote exhaust and normal exhaust. To identify the one you have purchased, go to the following chart with your product code, which can be found on the nameplate of the pump, in the case externally controlled see the parts drawing for your pump on pages 12-15.
Page 18
Finally, after applying some mounting sealent in the diaphragm washer (Pos.1), thread the washer and thighten as much as possible with the hands. 855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 19
Finally, assamble the diaphragm lids (Pos.8) following intructions and torques given in the hytrel and Santoprene diaphragm replacement. R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 20
855 819 R. 03/12 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 21
3. Replace the kit following the correct order shown in the assembly drawing. Reassemble the pump in reverse order. Maximum tightening torque 137.7 lbf·in (15 N·m). R. 03/12 855 819 Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533...
Page 22
Directflo : upgrading to quick coupling diaphragms ® 1. Please refer to the pump operation and maintenance manual and follow the diaphragm replacement procedure to remove the diaphragms. 2. Pull out the central shaft. 3. Push in a quick coupling shaft (for stainless steel shafts, DF30 = part 855431, DF50 = part 855432, DF100 = part 855433) 4.
Page 23
New quick coupling diaphragm nut New quick coupling tempered central shaft Conductive PTFE central bushing New scraper geometry in the central bushing DF pumps manufactured after January 2013 (S/N 328099/001 and above) 2 ...