Page 1
INSTRUCTION MANUAL LIQUID RING PUMP TRUCK MASTER 1700 ® INSTRUCTION MANUAL FOR SAMSON LIQUID RING PUMP TRUCK MASTER 1700 • Service • Technical data • Design of a system • Troubleshooting • Installation and start-up • Spare parts The English version of the instruction manual is the legally binding version.
Truck Master 1700 CONTENTS Introduction ..........................4 Declaration of conformity ......................4 Explanation of warning symbols ....................5 Field of application ........................5 Disposal ..........................5 Technical data .......................... 6 Dimensions ..........................6 Specifications .......................... 7 Power consumption and output ....................8 2.3.1...
Page 3
Truck Master 1700 Service, operation, maintenance and inspection intervals..........21 Draining the liquid separator and the pump ................21 Check grease cartridges ....................... 21 Winterization ......................... 21 Lubrication of bearings ......................22 Inspection and cleaning of water supply pipe ................ 22 Inspection and cleaning of internal channels ................
Truck Master 1700 1 INTRODUCTION 1.1 Declaration of conformity D D e e c c l l a a r r a a t t i i o o n n o o f f C C o o n n f f o o r r m m i i t t y y...
1.4 Disposal Samson’s liquid ring pump is manufactured so that most of the device can be reused/recycled. Samson Pumps offer users of the company’s pumps the option of returning used pumps to be restored or scrapped. Alternatively, the pump must be taken apart and sorted into its separate components, by the customer (see section 7 for the pump’s material).
Truck Master 1700 2.2 Specifications A failure to meet these specifications may result in damage to the pump Description Minimum Maximum Ambient temperature, operation Below 0°C - see chapter 5.3 -20°C 55°C Ambient temperature, storage -20°C 55°C Humidity 100% Intake temperature, suction side 60°C...
Truck Master 1700 2.3.3 Correction factor - Temperature When the temperature of the water exceeds 15°C, the pump’s capacity will be affected with respect to the specified values. To determine the output at a higher temperature, the correction factor can be used.
Truck Master 1700 2.4 Handling and transport The pump must not be used if it is damaged or the identification plate is missing The pump must be transported in such way that it is not exposed to vibrations and impacts that can overload the bearings.
Truck Master 1700 2.5 Pump storage and draining procedure A failure to comply with the requirements for storing the pump may result in internal damage to the device If the temperature is below freezing point of the water, it could damage the pump.
Truck Master 1700 3 DESIGN OF A SYSTEM DOC1627390 Pos. Description Liquid ring pump Non return valve 4-way valve Vacuum control valve Water control valve Fan cooler Liquid separator Dome valve DOC9091B...
Truck Master 1700 3.1 Function and design of a liquid separator Together with the air there will be a water flow out of the pump up to 6 m3/h. The water will be separated from the air in the liquid separator.
Truck Master 1700 3.2 Air cooling with fan cooler Compression of air inside the liquid ring pump will create heat that is transferred to the water. Therefore, it can be necessary to install a fan cooler depending on the expected use, the climate etc. The time it takes to heat up the water also depends on for example ambient temperature, suction pressure, amount of water and the cooling effect in the truck itself.
Truck Master 1700 3.3 Fan cooler The fan cooler will increase the heat output from the construction and thereby stabilize the temperature at a lower level. However, this cooler will use the air to cool down the water and therefore we will always see that the temperature will be stabilized above the ambient temperature.
Truck Master 1700 Summary Pump model Description Truck Master 1700 Heat input from technical specifications 30 kW in Pump Ambient temperature 28°C Maximum Working Temperature of the water. This is determined by you. The temperature 40°C has influence on the pump performance Temperature difference Δ...
Truck Master 1700 3.6 Cavitation When the temperature reaches the boiling point of the water, steam bobbles will be created in the liquid ring. These bobbles cannot exist when they enter the discharge side of the pump and therefore they will collapse.
Truck Master 1700 4 INSTALLATION AND START-UP 4.1 Securing the pump Installation requirements must be observed, otherwise there is a risk of damage The pump must be installed on a stable foundation, which must be level and stable, so that the pump is not twisted or exposed to a profile distortion.
Truck Master 1700 4.3 Connecting the water The water must be connected to the pump at the hose connection (C), see illustration below. If required, the hose nipple can be dismounted from (C) and mounted on desired location (A, B or D).
Truck Master 1700 4.5 Prior to start-up • Do not start the pump without water, as this will damage the mechanical shaft seals • Do not start the pump if it is completely filled with water • Do not start the pump before the grease cartridges have been activated, as this can damage the pump (if equipped) •...
Truck Master 1700 5 SERVICE, OPERATION, MAINTENANCE AND INSPECTION INTERVALS A failure to observe the inspection intervals described in table below may result in damage to the pump Section Operation Interval Drain liquid separator and pump to remove contaminants Daily...
Truck Master 1700 5.4 Lubrication of bearings Over-lubrication of bearings may result in bearing damage! Do NOT exceed the amount of grease specified below! The bearings must be lubricated with grease of type SKF LGWA2, per 500 duty hours. It is recommended to lubricate the bearings while pump is running.
Truck Master 1700 6 TROUBLESHOOTING Problem Cause Effect Corrective measure The pump is unable to • Water control valve is • Reduced output • Check water control create a vacuum closed valve • The pump can become • The pump is not damaged during •...
Truck Master 1700 7 SPARE PARTS AND TOOLS 7.1 Marking and identification The pump is equipped with an identification plate as shown below. CE CONFORMITY MARK ORDER CONFIRMATION NO. / A NO. MANUFACTURING DATE / SERIAL NO. PRODUCT CODE Configuration example:...
Truck Master 1700 7.5 Gasket set DOC1654050 Pos. Part number Description Qty. Material 1654028 Gasket for pump cover / housing 5 mm Rubber NBR 1654033 Gasket for pump housing / flow plate 1 mm Paper Oakenstrong 1654034 Gasket for shell / flow plate 0,5 mm...
Truck Master 1700 7.6 Special tool set DOC1629353_1A DOC1629353_1A Pos. Part number Description Qty. Material 1629239 Mandrel radial shaft seal Ø50 + Ø60 Plastic 1629355 Machined bearing cap complete Steel 1629107 Bearing mounting tool set NDE Steel 1629108 Bearing mounting tool set DE...
Page 36
Gamma Series is designed to handle the harshest industrial vacuum jobs. At the core of Samson Pumps’ activity is the strong belief that our liquid ring vacuum pumps must be of superlative quality for our customers to focus on what they do best.
Need help?
Do you have a question about the TRUCK MASTER 1700 and is the answer not in the manual?
Questions and answers