Breaker
Connect the AC power supply from the 3-phase power supply equipment of the building to the
lamp power supply (NC-32PS01) via a breaker. Determine the breaker capacity depending on
the voltage of the AC power supply used.
The breaker capacity will be as follows depending on the power supply voltage.
AC power supply voltage used
200-230V
380-415V
Input voltage selection switch
- Set the input voltage selection switch for the lamp power supply corresponding to the voltage
of the AC power supply used. Set it as follows:
AC power supply voltage used
200-230V
380-415V
The factory default setting is 400 V.
When using NC-32PS02
Single phase AC power supply equipment
Single phase AC power supply equipment
- Do not use any voltage other than those shown below for the AC power supply connected to
the lamp power supply (NC-32PS02).
200 V AC to 240 V
Switch setting
200 V
400 V
Breaker
Single phase
AC power cable
AC single phase power of 50/60 Hz
Breaker current capacity
40 A or more
20 A or more
Lamp power supply
2. Setting Up Your Projector
Lamp Power Supply
(NC-32PS02)
49