i would like to know the correct wat to vent this pump
1 comments:
Mr. Anderson
February 10, 2025
The Liberty Pumps 404 should be vented using an unrestricted vent pipe with a diameter of at least 1-¼ inches. The vent pipe should be connected directly to a building or house vent. A union should be installed in the vent pipe to allow for easy removal if needed. One-way quick-vents or air admittance valves should not be used, as they do not guarantee proper fixture performance. If the top port is used for venting, a 1/8-inch hole should be drilled through both the unit and vent pipe to prevent air pockets that could interfere with alarm float activation.
Page 3
To reduce the risk of electric shock, be certain that it is connected to a Ground Model 404: Do not use pumps with fluid over 140°F (60°C). Fault Circuit Interrupter (GFCI) receptacle that meets the Operating the pump in fluid above this temperature can latest requirements per UL 943 including Auto-Monitoring or overheat the pump, resulting in pump failure.
Page 4
Either can be used as a vent or inlet. Using the Inlet or Vent appropriate piping (1-1/2” on 404 and 404CV models and 2” on 404L and all 405 models), connect the fixture (i.e., laundry tub, Alternate Inlet or Vent basement sink, washing machine) to the pump.
Page 5
Provision is made for a vent stack to allow extra volume for high Models 404 and 405 with /A or /A-EYE come with a Liberty Pumps suds conditions, and to ensure proper drainage of the fixture. The alarm.
Page 7
Piping to house structure is too rigid. hose to absorb noise. *NOTE: Liberty Pumps, Inc. assumes no responsibility for damage or injury due to disassembly beyond float removal in the field. Disassembly, other than at Liberty Pumps or its authorized service centers, automatically voids warranty.
Page 8
Liberty Pumps, Inc. shall not be liable for any loss, damage, or expenses resulting from installation or use of its products, or for indirect, incidental, and consequential damages, including costs of removal, reinstallation or transportation.
Need help?
Do you have a question about the 404 and is the answer not in the manual?
Questions and answers
i would like to know the correct wat to vent this pump
The Liberty Pumps 404 should be vented using an unrestricted vent pipe with a diameter of at least 1-¼ inches. The vent pipe should be connected directly to a building or house vent. A union should be installed in the vent pipe to allow for easy removal if needed. One-way quick-vents or air admittance valves should not be used, as they do not guarantee proper fixture performance. If the top port is used for venting, a 1/8-inch hole should be drilled through both the unit and vent pipe to prevent air pockets that could interfere with alarm float activation.
This answer is automatically generated