Automatic drain pumps
Hide thumbs Also See for 404:

Advertisement

Quick Links

Installation Manual
Automatic Drain Pumps
Models
404
1/3 hp Residential 115V
404
404/A
• with Alarm
404/A-EYE
• with NightEye® Alarm
404CV
• with Check Valve
404CV/A
• with Check Valve and Alarm
404CV/A-EYE
• with Check Valve and NightEye® Alarm
404L
• with Larger Ports
404L/A
• with Larger Ports and Alarm
404L/A-EYE
• with Larger Ports and NightEye® Alarm
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 800-543-2550
fax: 585-494-1839
www.libertypumps.com
All Units Contain
Certified Pump
Copyright © Liberty Pumps, Inc. 2019 All rights reserved.
405
1/2 hp Commercial High Temp 115V
405
405HV
• High Voltage 230V
405/A
• with Alarm
405/A-EYE
• with NightEye® Alarm
Meets UPC
404CV Models Only
7212000F
ASME A112.3.4
CSA B45.9

Advertisement

loading
Need help?

Need help?

Do you have a question about the 404 and is the answer not in the manual?

Questions and answers

Robert w Schuttrumpf
February 4, 2025

i would like to know the correct wat to vent this pump

1 comments:
Mr. Anderson
February 10, 2025

The Liberty Pumps 404 should be vented using an unrestricted vent pipe with a diameter of at least 1-¼ inches. The vent pipe should be connected directly to a building or house vent. A union should be installed in the vent pipe to allow for easy removal if needed. One-way quick-vents or air admittance valves should not be used, as they do not guarantee proper fixture performance. If the top port is used for venting, a 1/8-inch hole should be drilled through both the unit and vent pipe to prevent air pockets that could interfere with alarm float activation.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Liberty Pumps 404

  • Page 1 • with Larger Ports and NightEye® Alarm 7000 Apple Tree Avenue Bergen, NY 14416 ASME A112.3.4 ph: 800-543-2550 CSA B45.9 fax: 585-494-1839 All Units Contain Meets UPC www.libertypumps.com Certified Pump 404CV Models Only Copyright © Liberty Pumps, Inc. 2019 All rights reserved.
  • Page 2 Pump Model #: For replacement manual, visit libertypumps.com, or contact Liberty Pumps at 1-800-543-2550. Pump Serial #: Retain dated sales receipt for warranty. Manufacture Date: Install Date: 2 | EN Copyright © Liberty Pumps, Inc. 2019 All rights reserved. 7212000F...
  • Page 3 To reduce the risk of electric shock, be certain that it is connected to a Ground  Model 404: Do not use pumps with fluid over 140°F (60°C). Fault Circuit Interrupter (GFCI) receptacle that meets the Operating the pump in fluid above this temperature can latest requirements per UL 943 including Auto-Monitoring or overheat the pump, resulting in pump failure.
  • Page 4 Either can be used as a vent or inlet. Using the Inlet or Vent appropriate piping (1-1/2” on 404 and 404CV models and 2” on 404L and all 405 models), connect the fixture (i.e., laundry tub, Alternate Inlet or Vent basement sink, washing machine) to the pump.
  • Page 5 Provision is made for a vent stack to allow extra volume for high Models 404 and 405 with /A or /A-EYE come with a Liberty Pumps suds conditions, and to ensure proper drainage of the fixture. The alarm.
  • Page 6 MODEL 404 AND 405 PERFORMANCE CURVES AT 80°F WATER TEMP MODEL 405 Model 405 @ 180°F MODEL 404 FLOW (GPM) Figure 8. Performance Curves for Models 404 and 405 6 | EN Copyright © Liberty Pumps, Inc. 2019 All rights reserved. 7212000F...
  • Page 7 Piping to house structure is too rigid. hose to absorb noise. *NOTE: Liberty Pumps, Inc. assumes no responsibility for damage or injury due to disassembly beyond float removal in the field. Disassembly, other than at Liberty Pumps or its authorized service centers, automatically voids warranty.
  • Page 8 Liberty Pumps, Inc. shall not be liable for any loss, damage, or expenses resulting from installation or use of its products, or for indirect, incidental, and consequential damages, including costs of removal, reinstallation or transportation.