G4163
WLL
A
B
C
T
mm
mm
mm
6.5
22
25
52
12.5
32
35
72
25
45
50
103
55
65
70
145
3.2. Use
- Use the V-LINK only in tracti on.
- The dynamometer can be used in all directi ons, including horizontally.
- Rapid changes in temperature may aff ect the accuracy. It is therefore recommended that the
dynamometer is kept in stable temperature 20-30 minutes before use.
3.3. Uninstalling
- When uninstalling, fi rst make sure that any tracti ve strain has been eliminated.
- Make sure to handle the dynamometer safely and avoid damage.
- When operated in corrosive environments wipe off all the external surfaces with a damp cloth.
- For opti mal maintenance apply a thin layer of light oil, e.g. WD 40.

3.4 Overload

In case of an overload it is imperati ve to completely release the stress on the
dynamometer and conduct the following overload test.
Overload test: Turn the dynamometer off and on. If it indicates a value
"DANGER"
much higher or lower than the usual starti ng value, it has been permanently
damaged. In this case, it is imperati ve to have it checked by Vetec's service
department before further use.
D
E
F
G
mm
mm
mm
mm
22
36
83
58
32
51
115
83
45
74
178
126
65
105
260
180
- 5 -
H
I
J
K
mm
mm
mm
mm
144
130
102
22
201
178
147
30
300
249
216
23
433
330
310
32
Weight
Kg.
1.77
4.91
14.22
39.59