Page 2
Front Back A Capacity / Product brand H Capacity / Serial no. engraved B Red LED display USB port (only for charging) C Operating panel Safe Working Load (SWL) D Manufacturer name K Item no. E ON/OFF button Read manual. CE F Tare button M Manufacturer name G Hole for shackle...
Page 3
Quick start guide The instructi ons contained in this quick guide do not replace the full manu- al. Make sure to read the whole manual carefully and correctly before use.. On/off Press ON/OFF to turn on and off . Once pressed, the display shows the soft - ware version number for a few seconds.
Failure to follow these warnings could result in serious injury and property damage. Every use should be carried out according to current regulations in the country of use. Vetec A/S is not responsible for local regulations not being followed.
2.3 Remote wireless display Duplex communicati on and a long range enable measurements to be read from a long distance. To avoid interference the dynamometer and display can be connected using 99 diff erent channels. Item no. WRDX01 Applicati on areas Only applicable with a V-LINK dynamometer.
3.1. Installati on The V-LINK must be fi tt ed with shackles that comply with the SWL of the dynamometer and the applicable legislati on in the country of use. Vetec A/S recommends Green Pin standard Shackles, G4163 and G-4161.
Overload test: Turn the dynamometer off and on. If it indicates a value ”DANGER” much higher or lower than the usual starti ng value, it has been permanently damaged. In this case, it is imperati ve to have it checked by Vetec’s service department before further use. - 5 -...
4. Basic setti ngs Tænk og sluk Press ON/OFF to turn on and off . Once pressed, the display will show the soft ware version number for a few seconds. Then the untared value will show. *The dynamometer will not automati cally turn off if not used. Tare functi on To acti vate the tare functi on press and hold →0←...
5. Menu / Advanced settings 5.1. Peak hold (Menu 1) Activate peak hold Press the ON/OFF button. Press and hold MENU until the display shows 1. Select 1 (Menu 1) by pressing ENTER. The display now shows PEoFF (Peak hold off). Press to go to PE on (Peak hold on).
Deacti vate peak hold Press and hold MENU unti l the display shows 1. Select 1 by pressing ENTER. The display now shows PE on. Press unti l the display shows ·PEoFF. Press ENTER to turn off Peak Hold. Press RETURN to go to default setti ngs. *Peak hold will not deacti vate when the dynamometer is turned off .
7. Charging V-LINK is charged using a standard high quality USB charger. Always on stock at Vetec or available in any store. Charge the dynamometer in your car, connected to your computer or using a wall charger. As the charger is not waterproof charging the unit in a safe dry place is recommended.
To prevent damage to the dynamometer, make sure that repairs and recalibration are carried out by qualified personnel. It is recommended that recalibration and repairs are done at Vetec’s service department located in Denmark or by authorized partners. Contact Vetec’s service department for further information.
In the event of a defect during the warranty period, the dynamometer must be returned, with freight (and all duti es and taxes) prepaid by the Buyer. Vetec A/S or the distributor will, according to their choice, repair or replace the defecti ve unit.