Symptom
Cause and Remedy
Color balance is incorrect.
• Picture has not been adjusted properly.
c Adjust the picture (see page 25).
• Projector is set to wrong color system.
c Set COLOR SYS in the PICTURE CTRL menu to match the
color system being input (see page 25).
The picture is too dark.
• Contrast or brightness has not been adjusted properly.
c Adjust the contrast or brightness in the PICTURE CTRL menu
properly (see page 25).
The picture is not clear.
• Picture is out of focus.
c Adjust the focus (see page 22).
• Condensation has occurred on the lens.
c Leave the projector for about two hours with the power on.
The picture appears too
• SHIFT in the INPUT SETTING menu has not been adjusted
small on the screen.
properly.
c Adjust SHIFT in the INPUT SETTING menu properly (see
page 26).
The picture flickers.
• DOT PHASE in the INPUT SETTING menu has not been adjusted
properly.
c Adjust DOT PHASE in the INPUT SETTING menu properly
(see page 26).
Sound
Symptom
Cause and Remedy
No sound.
• Cable is disconnected or the connections are wrong.
c Check that the proper connections have been made (see page
15).
When sound is input
• Monaural sound is being input through the AUDIO connector.
through AUDIO connector,
c Input stereo sound.
sound comes through one
channel only.
Remote Commander
Symptom
Cause and Remedy
The Remote Commander
• The Remote Commander batteries are dead.
c Replace with new batteries (see page 12).
does not work.
• The front/rear remote control detector is near the fluorescent lamp.
c Change the setting of SIRCS RECEIVER in the SET SETTING
menu (see page 28).
The joystick, R CLICK, or
• The mouse port on the computer does not recognize the mouse
L CLICK key does not
cable.
c Restart the computer.
function.
Others
Symptom
Cause and Remedy
The LAMP/COVER
• The lamp cover or the air filter cover is detached.
indicator flashes.
c Attach the cover securely (see page 29).
32
GB
Troubleshooting
Symptom
Cause and Remedy
The LAMP/COVER
• The lamp has reached the end of its life.
indicator lights up.
c Replace the lamp (see page 29).
• The lamp becomes a high temperature.
c Wait for 90 seconds to cool down the lamp and turn on the
power again (see page 29).
The FAN/TEMP indicator
• The fan is broken.
flashes.
c Consult with qualified Sony personnel.
The FAN/TEMP indicator
• The internal temperature is unusually high.
lights up.
c Check to see if nothing is blocking the ventilation holes.
Both the LAMP/COVER
• The electrical system breaks down.
and FAN/TEMP indicators
c Consult with qualified Sony personnel.
light up.
Warning Messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
Meaning and Remedy
High temp.!
• Internal temperature is too high.
c Turn off the power.
Lamp off in 1 min.
c Check to see if nothing is blocking the ventilation holes.
Frequency is out of range!
• This input signal cannot be projected as the frequency is out of the
acceptable range of the projector.
c Input a signal that is within the range of the frequency.
• The resolution setting of the output signal of a computer is too
high.
c Set the setting of output to SVGA (see page 15).
Please check INPUT-A
• You have input RGB signal from the computer when INPUT-A in
setting.
the SET SETTING menu is set to COMPONENT.
c Set INPUT-A correctly (see page 27).
Caution Messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
Meaning and Remedy
NO INPUT
• No input signal
c Check connections (see page 15).
Not applicable!
• You have pressed the wrong key.
c Press the appropriate key.