7
Appendix B FRUs and compatibility
matrixes
CAUTION:
• Select fan modules and power supplies with airflow directions that meet the ventilation
requirements at the installation site. As a best practice, make sure the power supplies and fan
modules have the same airflow direction.
• Do not install fan modules of different models on the same switch. To guarantee adequate heat
dissipation, install five fan modules of the same model on the switch.
• Do not install power supplies of different models on the same switch. As a best practice, install
two power supplies of the same model on the switch for 1+1 power supply redundancy.
Table7-1 Compatibility matrix between the FRUs and HPE 5944 48XGT 6QS28 switch
FRUs
Power supplies
PSR450-12A
PSR450-12A1
PSR450-12D
Fan modules
HPE 5944 power-to-port fan module
HPE 5944 port-to-power fan module
Power supplies
CAUTION:
When the switch has two power supplies in 1+1 redundancy, you can replace one of them without
powering off the switch. To avoid device damage and body injury, make sure the power supply to be
replaced is powered off before you replace it.
Table7-2 Power supply specifications
Power supply
PSR450-12A (with an
airflow direction from
the power supply side
to the port side)
PSR450-12A1 (with
an airflow direction
from the port side to
the power supply
side)
Specifications
•
AC input:
Rated input voltage range: 100 to 240 VAC @
50/60 Hz
Max input voltage range: 90 to 290 VAC @ 47 to
63 Hz
Max output power: 450 W
•
DC input:
Rated input voltage range: 240 VDC
Max input voltage range: 180 to 320 VDC
Max output power: 450 W
7-38
Part No.
HPE 5944 48XGT 6QS28
JL593A
Yes
JL592A
Yes
JL688A
Yes
JL838A
Yes
JL837A
Yes
Remarks
For more information
about the power
supplies, see HPE
PSR450 Power
Supply Series User
Guide.