Table of Contents

Advertisement

TTI884COM

Troubleshooting

Therefore check the product using this section. In most cases the problem can
be solved quickly.
WARNING! Only perform the steps described within these instructions!
All further inspection, maintenance and repair work must be performed
cannot solve the problem yourself!
Problem
1. Product does
not start
2. Product does
not reach full
power
3. Unsatisfac-
tory result
4. Product sud-
denly stops
MNL_18V 2X 2AH Li-ION BRUSHED COMBI DRILL_V2_211220.indd 33
Possible cause
1.1. Forward / reverse
rotation control switch
at centre lock position
1.2. Battery pack not
properly attached
1.3. Battery pack discharged
1.4. Battery pack damaged
1.5. Other electrical defect
to the product
2.1. Battery pack capacity
too low
2.2. Air vents are blocked
2.3. Incorrect torque ring
setting
3.1. Drill / driver bit is worn
3.2. Drill / driver bit not
suitable for intended
operation
4.1. Product overloaded
4.2. Battery pack discharged
4.3. Battery pack too hot
Troubleshooting
Solution
1.1. Push forward / reverse
rotation control switch
to left / right
1.2. Attach properly
1.3. Remove and charge
battery pack
1.4. Replace with a new one
of the same type
1.5. Check by a specialist
electrician
2.1. Charge battery pack
2.2. Clean the air vents
2.3. Choose higher torque
ring setting
3.1. Replace with a new one
3.2. Use suitable drill / driver
bit
4.1. Remove the product
from the workpiece and
switch it on again
4.2. Remove and charge
battery pack
4.3. Remove battery pack
and let it cool down