Heating Priority Wiring For Three Phases Pump - Hayward SUMHEAT HP5131DT3 Installation Instructions Manual

Swimming pool heat pump unit
Table of Contents

Advertisement

6. APPENDIX (continued)

6.3 Heating priority wiring for three phases pump

Remove the front panel to access the terminal board.
L1
L2
1L1 3L2 5L3
2T1 4T2
Terminals 1 and 2 deliver a potential-free dry contact,
230V
/ 50 Hz, no polarity.
Wire terminals 1 and 2 as indicated in the diagram
above, to activate the operation of the filtration pump
in 2-minute cycles each hour if the temperature of the
pool is lower than the set point.
Never connect the power supply of the filtration
pump directly to terminals 1 and 2.
30
L3
N
13N0
A1
6T3
14N0
A2
L3
L2
L1
Three phases pump
4
5
6
7
1
2
3
8
=
=
R
S
Power supply
430V 3N
Dry contact
7 A max
K2
= =
=
=
T N
1
2
/ 50Hz
= =
3 4