Heating Priority Connections Single-Phase Pump - Hayward HP3005AT1RM Installation Instructions Manual

Swimming pool heat pump unit
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 30
6. APPENDICES (continued)

6.2 Heating priority connections Single-Phase Pump

Dry contact 7 A max
OUT2
Power supply
230V
/ 50Hz
Monophasic pump
Terminals 1 and 2 deliver a potential-free dry contact,
230 V
/ 50 Hz, no polarity.
Wire terminals 1 and 2 as indicated in the diagram
above, to activate the operation of the filtration pump
in 2-minute cycles each hour if the temperature of the
pool is lower than the set point.
Never connect the power supply of the filtration
pump directly to terminals 1 and 2.
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents