Reset Button Pressed and Released
About 1 second
About 8 seconds
Be sure that you back up the current configuration of PoE Injector Hub before resetting PoE
Injector Hub or else the entire configuration will be erased when pressing the "RESET" button.
2.1.2 LED Indicators
The front panel LEDs indicates instant status of system power, Management port Link/Active and PoE port links, helps
administrator to monitor and troubleshoot when needed.
LED
Color
FAN1 Failed
Green
FAN2 Failed
Green
Power1
Green
Failed
Power2
Green
Failed
Power
Green
PoE In-use
Green
2.1.3 Injector Rear Panel
The rear panel of the PoE Injector Hub indicates an AC inlet power socket, which accepts input power from 100 to 240V
AC, 50/60Hz.
Figures 2-1-4 & 2-1-5
The following is the summary table of Reset button
Reboot the PoE Injector Hub.
Reset the PoE Injector Hub to Factory Default configuration.
The PoE Injector Hub will reboot and load the default IP
settings as shown below.
Function
Lights to indicate FAN1 has stopped.
Lights to indicate FAN2 has stopped. (Only for HPOE-2400G)
Lights to indicate power supply 1 has failed.
Lights to indicate power supply 2 has failed. (Only for HPOE-2400G)
Lights to indicate power on.
Lights to indicate that the port is in use and supplying 48V DC power.
show rear panel of the PoE Injector Hub.
Figure 2-1-4: HPOE-1200G Rear Panel
Figure 2-1-5: HPOE-2400G Rear Panel
User's Manual of HPOE-1200G / HPOE 2400G
functions:
Function