Card-Edge Connectors; Gas-Tube Protectors; Thermal Deployment Limits; Hre-602 Replacement Kit - ADC HRE-602 List 1 User Manual

Table of Contents

Advertisement

150-602-100-04

Card-Edge Connectors

Figure 3 on page 5
details the wiring specifications for both card-edge connectors.

Gas-Tube Protectors

The eight replaceable gas-tube protectors are equivalent to a TII 47BT and have a breakdown voltage ranging from
300 V to 500 V. The breakdown voltage is a function of voltage rise-time. The tubes can withstand at least
400 repetitions at 10/1000 rise-time with 500 Amp discharges.

Thermal Deployment Limits

The HRE-602 can be deployed in an ambient temperature up to +135 °F (+57.2 °C) without solar load when
housing one doubler. Reduce these limits by +10 °F (+12.2 °C) when housing two HDU-409 doublers.
These requirements comply with Bellcore standards, which require HDSL equipment placed in
outdoor cabinets to operate in a temperature of -40 °F (-40 °C) outside the housing without solar
load and +115 °F (+46.1 °C) with maximum solar load and maximum power dissipation.
Full solar load is equal to maximum sunlight exposure as defined in Bellcore's Technical
Advisory TR-TSY-000057.
HRE-602 R
EPLACEMENT
A replacement kit containing twenty TII 47BT gas-tube protectors is available from ADC
(part number 132-1028-01).
HRE-602 List 1 and List 1B
K
IT
"Appendix B - Product Support" on page 12
September 29, 2000
Product Description
details the ordering information.
7