Download Print this page

JLG LT3 Operation And Safety Manual page 18

Lighting tower

Advertisement

1.5
1.5.6
LIGHTS & ENGINE CONTROL
Fig 1.5.10
1)
Manual Start/Stop Mode -Summary
Manual Start/Stop is initiated by the
following pushbutton sequence.
Start
A) press
wait for the engine start-up period
wait for the machine to warm-up
B) press
Stop
C) press
to shut-down genset
wait for the machine to complete
the shutdown sequence.
2) Auto Start/Stop Mode - Summary
A) press
for each screen shown in Fig 1 to Fig 3
press
and
press
or
1001281353
Oshkosh Corporation Classification ‐ Restricted 
MACHINE OPERATION
JLG LT
then
to turn-on each light
to select
to confirm
JLG Industries (Australia) Pty Ltd
Oshkosh Corporation
3
B) 10 seconds before engine start-up
time, an audible alarm sounds
At pre-set start time, the engine cranks
C) wait for the generator to reach the
"on-load" requirements.
D) When the "stop delay" time is reached
all lights will turn off in sequence.
When all lights are off, the engine runs
through a cool-down cycle before
stopping.
Page 1-18