BEFORE STARTING
1. Read safety instructions at the beginning of manual.
2. Check power plug and contact for dirt, rust, deformation
and breakage.
3. Check power cable for wear, crushing, crack, etc.
4. Open the output outlet cover to check inside and
terminal part for dirt, etc. Check bolts and nuts used on
inverter for looseness, deformation, etc. Also check the
output outlet cover for smooth open/close movement.
5. Check circuit protector switch to see if it properly
switches ON and OFF, and the green LED turns ON.
After inspection, always turn the switch OFF.
6. Connect to a vibrator and check to see if the vibrator
operates normally.
7. Check anti-vibration rubber for deformation and cracks.
8. Check conduction resistance between power plug
contacts when circuit protector is OFF.
For safety purpose, the input voltmeter needle moves
when the power plug is inserted into the power source
outlet even if the circuit protector is turned OFF.
Measure conduction resistance between power plug
contacts. The tester needle will point to around 200
to 300Ω. This is the impedance (resistance) of the
voltmeter, not conduction trouble. This value pointed by
the tester may vary slightly depending on the detection
method and accuracy of the tester.
PAGE 14 — FU162A INVERTER • OPERATION MANUAL — REV. #0 (05/12/22)