Firman P04001 Operator's Manual page 19

Gasoline portable generator

Advertisement

5. Stopping the generator
1. Turn off and remove all electrical loads.
Never stop the generator with electrical devices plugged in and turned on.
Never stop the engine by moving the choke to the start position.
Let the generator run at no-load for one minute to stabilize internal temperatures of the engine
and generator.
2. Remote Start Operation
Skip this step and go to step 3, if you are not using Remote Start to shut down the engine.
Push and release the "STOP" button on the remote control. The generator will run for an additional
15 seconds as it goes through a cool down cycle before shutting off.
3. Electric Start and Recoil Start Operations
Flip the engine switch to"OFF"(O) position.
4. Flip the battery switch to "OFF"(O) position.
NOTICE
The battery switch always should be in "OFF"(O) position at the end of use to prevent battery drain.
English
STOP
18
STOP
Customer Service: 1-844-FIRMAN1