Pattern Mode - Ecco ED3777 Series Assembly, Installation And Operation Instructions

Led directionals
Table of Contents

Advertisement

Flash Pattern Selection:
The flash pattern can be selected by powering the individual flash pattern mode and holding the blue wire to the black wire.
- A quick tap will increment by one pattern.
- 1-3 seconds to go to the previous pattern
- 3-5 seconds to return to the factory default pattern
- 5+ seconds to set to the last flash pattern
Synchronization:
The directional is capable of syncing with other compatible ECCO products by setting the desired flash pattern on each unit individually. It is also
strongly recommended that the same rate and style of flash pattern be used on all synced units to produce the most effective warning pattern.
NOTE: To operate sumultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units must be set to have the
opposite phase (A + B or B + A). Then, connect the yellow sync wires together and check that the units are flashing in a synchronized manner as
expected. If a pattern on one unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until
the correct pattern is selected.
NOTE: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.
SINGLE COLOR Flash Pattern Chart/DE UN SOLO COLOR Tabla de patrones de destello/COULEUR UNIQUE Tableau des effets clignotants
PATTERN
MODE
DESCRIPTION
1-Default Single Flash 75FPM sim. Phase1
1
2
Single Flash 75FPM sim. Phase2
3
Single Flash 75FPM Alt.
4
Single Flash 120FPM sim. Phase1
2
5
Single Flash 120FPM sim. phase2
6
Single Flash 120FPM Alt.
7
Double Flash 75FPM sim. Phase1
3
8
Double Flash 75FPM sim. phase2
9
Double Flash 75FPM Alt.
10
Double Flash 120FPM sim. Phase1
4
11
Double Flash 120FPM sim. phase2
12
Double Flash 120FPM Alt.
13
Quad Flash 75FPM sim. Phase1
5
14
Quad Flash 75FPM sim. Phase2
15
Quad Flash 75FPM Alt.
16
Quad Flash 150FPM sim. Phase1
6
17
Quad Flash 150FPM sim. Phase2
18
Quad Flash 150FPM Alt
19
Triple 75FPM sim. Phase1
7
20
Triple 75FPM sim. Phase2
21
TripleAlter 75FPM Alt.
22
Quint Flash 150FPM sim. Phase1
8
23
Quint Flash 150FPM sim. Phase2
24
Quint Flash 150FPM Alt.
9
25
Steady - Single
10
26
Steady Burn
11
27
Modulation
12
28
2 Double Flash,2 Triple Alt.
13
29
4 Single Flash ,2 Quad Flash Alt.
SAE J595
SYNC
AMBER, BLUE, RED WHITE
yes
Class 1
Class 1
yes
Class 1
Class 1
yes
N/C
N/C
yes
Class 1
Class 1
yes
Class 1
Class 1
yes
N/C
N/C
yes
Class 1
Class 1
yes
Class 1
Class 1
yes
N/C
N/C
yes
Class 1
Class 1
yes
Class 1
Class 1
yes
N/C
N/C
yes
Class 1
Class 2
yes
Class 1
Class 2
yes
N/C
N/C
yes
Class 1
Class 2
yes
Class 1
Class 2
yes
N/C
N/C
yes
Class 1
Class 1
yes
Class 1
Class 1
yes
N/C
N/C
yes
Class 1
Class 2
yes
Class 1
Class 2
yes
N/C
N/C
NO
N/C
N/C
NO
N/C
N/C
NO
N/C
N/C
NO
N/C
N/C
NO
N/C
N/C
SAE J845
AMBER
BLUE
RED
CLASS 1S
CLASS 1S
CLASS 1S
CLASS 1S
140°
140°
160°
140°
140°
160°
N/C
N/C
N/C
120°
120°
140°
120°
120°
140°
N/C
N/C
N/C
140°
140°
160°
140°
140°
160°
N/C
N/C
N/C
120°
120°
140°
120°
120°
140°
N/C
N/C
N/C
N/C
N/C
60°
N/C
N/C
60°
N/C
N/C
N/C
N/C
N/C
60°
N/C
N/C
60°
N/C
N/C
N/C
140°
120°
160°
140°
120°
160°
N/C
N/C
N/C
N/C
N/C
60°
N/C
N/C
60°
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
CA T13
ECE R65
WHITE
AMBER, BLUE, RED AMBER, BLUE, RED
80°
Class B
80°
Class B
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
80°
Class B
80°
Class B
N/C
N/C
N/C
60°
60°
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
80°
N/C
80°
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
Class 1
Class 1
N/C
N/C
N/C
N/C
Class 1
Class 1
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
Page 4 of 6