MIXER RUN-IN
A. Before Starting:
•Check oil level and condition in the supply tank of the planetary gearboxes.
•Be sure all shields are properly in place.
•Cycle the unloading door and conveyor several times to fully charge the hydraulic system with oil.
•Be sure that the augersand reel can turn freely.
•Check for debris and/or any other items that could block or aff ect machine operation.
•Be sure that drain plugs are installed and the door is closed.
•Top off the hydraulic oil reservoir if required.
B.
Test run the mixer.
• Make sure mixer is empty, then start the mixer.
• Run for at least fi ve minutes at recommended RPM.
• Raise and lower the door and operate the conveyor/slide tray several times.
• Disengage the mixer and turn off the truck engine and remove the ignition key.
• Check the mixer drive components to be sure they are not abnormally hot.
C. After operating for ½ hour:
•Check that all bolts and fasteners are all tightened properly. (See Torque Spec.)
•Check that all wheel nuts are tight.
•Check the augers and reel. Remove all string, twine, or other entangled material.
•Check that no hoses are pinched, rubbing, or being crimped. Re-align as required.
•Check for oil leaks. Stop leaks before continuing.
•Lubricate all grease fi ttings.
D. After operating for 5 hours and 10 hours:
•Re-torque all wheel nuts, fasteners, and hardware.
•Check the augers and reel. Remove all string, twine, or other entangled material.
•Proceed with normal servicing and maintenance schedule as defi ned in the Maintenance Section.
E.
After operating 50-100 hours:
• Change suction fi lters to remove initial contaminants.
• Change the Auxiliary fi lter.
• Change the hydro fi lters
If any of these items are not running as indicated, immediately repair or contact your service representative.
ELECTRONIC SCALES
Scale Indicator: Refer to the electronic scale operators manual for adjustment information. The operator's manual
for the Electronic Scales should be kept with this manual. Additional scale manuals may be obtained through Sioux
Automation Center, Inc.
Load Cells: Should be kept clean and dry to ensure dependability. DO NOT POWERWASH!
Normal Scale Activity: Some warm up scale "drift" may occur after the scale is turned on but should zero balance within
10-15 minutes. Scale may zero shift over night due to temperature changes.