Proline SLC 116PEW Service Manual page 20

Condenser tumber dryer
Table of Contents

Advertisement

Code
Error message: The laundry not dried.
Consult the users to see if there
are wrong operations
N
Check whether the lint screen
is blocked
N
Check whether the
Thermostat
short circuit or cut off.
Y
Check whether the heater can
work normally
Code
Error message : Prompting there is no load or the loaded laundry has reached the requirements
for the dry setting.
Check if the load or clothes inside
the drum reached the setting
degree
N
Check if the sensor circuit lines are
connected normally
Y
Chek whether the brush is
installed properly
Code
Error message: NTC is short circuit or cut out
Check if the NTC terminals are
inserted properly
Y
Condenser Tumber Dryer
Thermostat
Humidity sensor
NTC connection
Y
Y
N
N
Y
N
Sensor lines
N
N
Page 19
SLC 116PEW
1
Do not put the clothes
dripping water into drum
2 Do not overload the dryer
3 Avoid adding clothes into
the drum when the drying
cycle is nearly finished
Clear the lint screen
Replace the Thermostat
Which can not work
Replace the heater which
can not work
Normally indicate the
information
Insert the sensor
The brush should be
installed close to the
drum and sensor slice
Insert the NTC terminals
properly