Dimensions; Minimum Clearance To Combustibles - Napoleon GDI3N-1 Installation Manual

Hide thumbs Also See for GDI3N-1:
Table of Contents

Advertisement

general information
EN
1.5

dimensions

front view
SAFETY BARRIER
1.6

minimum clearance to combustibles

This appliance must be recessed into a vented non-combustible wood-burning appliance (prefabricated or masonry)
only. The minimum appliance opening size in which the appliance is to be installed is:
Height
Width
Depth
The minimum allowable chimney fl ue size is 6" (152mm) round.
The minimum distance from the bottom of a combustible mantel projecting 3" (76mm) maximum from the wall to
the top of the appliance is 12" (30.4cm) (see "minimum mantel clearances" section).
note:
A non-combustible hearth must protrude a minimum of 12" (30.5cm) from the appliance.
A combustible hearth may be used if the appliance is raised 4" (102mm) above the hearth or if a Wolf Steel
raiser box is installed.
10
W415-4083 / 03.31.22
top view
GDI3-1
14 3/8" (36.6cm) + 2 3/4" (7cm) for
optional blower
GDI3E-1
GDIG3-1
21" (53.3cm)
29" (73.7cm)
right side view
back view
GDIX3-1
17 1/8" (43.5cm)