Napoleon GDI3N-1 Installation Manual
Hide thumbs Also See for GDI3N-1:
Table of Contents

Advertisement

Quick Links

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
GDI3N-1 / GDI3NE-1 / GDIG3N-1 / GDIX3N-1
GDI3P-1 / GDI3PE-1 / GDIG3P-1 / GDIX3P-1
INSTALLATION MANUAL
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
ADD MANUAL TITLE
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
CSA 2.33 AND ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
Oakville™ Series
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
PLACE BARCODE LABEL ON THE
IF SEPARATE MANUALS, ADD "PLACE
OWNER'S MANUAL
ENGLISH
FRENCH PG. 55
(GDIX3-1 illustrated)
W415-4083 / 03.31.22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GDI3N-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Napoleon GDI3N-1

  • Page 1 OWNER’S MANUAL BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-4083 / 03.31.22...
  • Page 2 safety information WARNING • This appliance is hot when operated and DANGER can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 safety information WARNING • Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance. • This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
  • Page 4: Table Of Contents

    table of contents general information adjustments rates and effi ciencies pilot burner adjustment rating plate information venturi adjustment operating and lighting instructions fl ame characteristics shut-off valve optional wall switch dimensions maintenance minimum clearance to combustibles 10 annual maintenance installation planning care of glass optional non-combustible care of plated parts...
  • Page 5 standard checklist Installer: please fi ll out appliance checklist in the owner’s manual. 1.0 general information When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
  • Page 6: General Information

    general information rates and effi ciencies GDI3-1 / GDI3E-1 Altitude (FT) 0 - 4500 Max. Input (BTU/hr) 24,500 Max. Output (BTU/hr) 13,475 GDIG3-1 Altitude (FT) 0 - 4500 Max. Input (BTU/hr) 24,000 Max. Output (BTU/hr) 14,808 GDIX3-1 Altitude (FT) 0 - 4500 Max.
  • Page 7 general information WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. • Provide adequate ventilation.
  • Page 8: Rating Plate Information

    Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 9: Operating And Lighting Instructions

    general information operating and lighting instructions GDI3E-1 GDI3-1 / GDIG3-1 / GDIX3-1 OPERATING INSTRUCTIONS / INSTRUCTIONS D’OPÉRATION OPERATING INSTRUCTIONS / INSTRUCTIONS D’OPÉRATION FOR YOUR SAFETY READ BEFORE OPERATING / POUR VOTRE SÉCURITÉ LIRE AVANT DE FAIRE FONCTIONNER FOR YOUR SAFETY READ BEFORE OPERATING / POUR VOTRE SÉCURITÉ LIRE AVANT DE FAIRE FONCTIONNER WARNING: DO NOT TURN ON IF CHILDREN OR OTHER AT RISK ATTENTION : NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES...
  • Page 10: Dimensions

    general information dimensions front view right side view SAFETY BARRIER back view top view minimum clearance to combustibles This appliance must be recessed into a vented non-combustible wood-burning appliance (prefabricated or masonry) only. The minimum appliance opening size in which the appliance is to be installed is: GDI3-1 GDI3E-1 GDIG3-1...
  • Page 11: Installation Planning

    2.0 installation planning installation planning WARNING • Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance. Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualifi...
  • Page 12: Levelling The Appliance

    installation planning levelling the appliance Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review your installation plans and/or installation. Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in this manual.
  • Page 13: Chimney Connection

    installation planning chimney connection Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and maximum vent lengths are 10' (3m) and 45' (14m) respectively.
  • Page 14: Gas Installation

    installation planning We recommend the following method of sealing off the damper area around the liner: Measure the throat of the appliance and mark this shape on a piece of 24 gauge sheet metal (fl ue cover). Cut a 6 3/4"...
  • Page 15: Finishing

    3.0 fi nishing fi nishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 16: Safety Barrier & Door Removal / Installation

    fi nishing safety barrier & door removal / installation WARNING • Glass may be hot. Do not touch glass until cooled. • If equipped with door latches that are part of a safety system, they must be properly engaged. Do not operate the appliance with latches disengaged.
  • Page 17: Log Placement

    fi nishing log placement 3.3.1 log placement for GDI3-1 / GDI3E-1 WARNING • Failure to position the logs in accordance with these diagrams or failure to use only logs specifi cally approved with this appliance may result in property damage or personal injury. •...
  • Page 18 fi nishing Pilot Shield Notch Place log #1 snug against the back wall, Place the two holes in log #3 on A1 and A2. Do PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. ensuring the notch fi ts around the pilot shield. not cover any burner ports.
  • Page 19 fi nishing Place log #7 along the centre of the lower Place log #8 along the right side of the lower PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. media tray. media tray. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS note: CONSISTENT THROUGHOUT.
  • Page 20: Log Placement For Gdix3-1

    Take the time to carefully position the glowing embers for a maximum glowing ef- “PHAZER™ logs [and glowing embers], exclusive to Napoleon/Continental, provide a unique and realistic fect. Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour glowing effect that is different in every installation.
  • Page 21 fi nishing Pilot Shield Notch Place log #1snug against the back wall, Place the two holes in log #3 on A1 and A2. Do PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. ensuring the notch fi ts around the pilot shield. not cover any burner ports.
  • Page 22: Decorative Panels

    fi nishing Place log #7 along the right side of the lower PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. media tray. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. IF SPACE IS LEFT OVER, USE THIS BOX TO IF SPACE IS LEFT OVER, USE THIS BOX TO SHOW CORRECT FINAL LOG PLACEMENT SHOW CORRECT FINAL LOG...
  • Page 23: Media Installation

    fi nishing media installation WARNING • Clean the glass media prior to installation. Before applying the cleaned glass, ensure that it is dry. • Do not change or substitute the glass media material provided with this appliance. If replacing, use only the replacement glass media available from your local authorized dealer / distributor.
  • Page 24: Charcoal Embers

    fi nishing charcoal embers WARNING • Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. • When supplied, charcoal embers, charcoal lumps and vermiculite are not to be placed on the burner. Randomly place the charcoal embers along the front and sides of the log support in a realistic manner.
  • Page 25: Receiver Removal

    fi nishing 3.11 receiver removal 1. Remove the right access panel from the side of the appliance. 2. Remove the front 2 screws from the inside edge (Fig. 3-5) and swing the control door open. note: If your opening is too small, you may need to pull the appliance out slightly.
  • Page 26: 4.0 Electrical Information

    4.0 electrical information wiring diagram (GDIG3-1 / GDIX3-1) WARNING • Do not wire 110 volts to the valve or wall switch. W415-4083 / 03.31.22...
  • Page 27: Wiring Diagram (Gdi3E-1)

    electrical information wiring diagram (GDI3E-1) WARNING • Do not wire 110 volts to the valve or wall switch. note: This appliance comes equipped with a battery back-up. If this back-up is used, install 4 ‘AA’ batteries (not supplied) into the holder and connect to the wire harness. Connect the battery holder to the wire harness before using the appliance.
  • Page 28: Operation (Millivolt - Gdi3-1)

    5.0 operation (millivolt - GDI3-1) electrical information WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 29: Operation (Electronic - Gdi3E-1, Gdig3-1, Gdix3-1)

    6.0 operation (electronic - GDI3E-1, GDIG3-1, GDIX3-1) electrical information WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 30: Pilot On Demand

    In order to start your pilot, turning the main burner on with the switch, remote or thermostat and then turning it off will reactivate the continuous pilot mode and reset the seven day timer. For further information, refer to www.napoleon.com/pilotondemand. (Fig. 2) (Fig.
  • Page 31: Acs Switch Location (Gdi3E-1 Only)

    operation (electronic - GDI3E-1, GDIG3-1, GDIX3-1) ACS switch location (GDI3E-1 only) ACS switch W415-4083 / 03.31.22...
  • Page 32: 7.0 Adjustments

    7.0 adjustments pilot burner adjustment Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: PILOT BURNER Inlet pressure can be checked by turning screw (A) counter- THERMOPILE 3/8”...
  • Page 33: Fl Ame Characteristics

    adjustments fl ame characteristics It is important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration provided. If any fl ames appear abnormal, call a service person. GDIG3-1 GDIX3-1 GDI3-1 / GDI3E-1 optional wall switch WARNING •...
  • Page 34: 8.0 Maintenance

    8.0 maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi...
  • Page 35: Annual Maintenance

    maintenance annual maintenance WARNING • Annual maintenance should be performed by a qualifi ed service technician • The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service. • Never vacuum hot embers. •...
  • Page 36: Care Of Plated Parts

    maintenance care of plated parts If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi rst time. Use an ammonia-free or vinegar-based cleaner and a towel to clean.
  • Page 37: Night Light™ Replacement (Gdig3-1 / Gdix3-1)

    maintenance night light™ replacement (GDIG3-1 / GDIX3-1) Your appliance comes equipped with our “Night Light™”. The light has been pre-wired and is controlled from the remote control. If the lamp or lens needs to be replaced, follow the instruc- tions below. Fig.
  • Page 38: Valve Train Replacement

    maintenance valve train replacement Remove safety barrier and glass door (see "safety barrier & door removal / installation" section). Remove media tray (see "media tray installation" section) and burners. Remove porcelain radiant panels (PRPs) or brick panels (if applicable). Remove the 14 screws holding the valve train in place (Fig.
  • Page 39: 9.0 Replacement Parts

    9.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 40 replacement parts W415-4083 / 03.31.22...
  • Page 41: Right Side Access Plate Assembly

    replacement parts W415-4083 / 03.31.22...
  • Page 42: Valve Train Assembly (Gdi3-1)

    replacement parts W415-4083 / 03.31.22...
  • Page 43: Valve Train Assembly (Gdig3-1)

    replacement parts W415-4083 / 03.31.22...
  • Page 44: Valve Train Assembly (Gdix3-1)

    replacement parts W415-4083 / 03.31.22...
  • Page 45: Valve Train Assembly (Gdi3E-1)

    replacement parts W415-4083 / 03.31.22...
  • Page 46: Fi Rebox Top Assembly

    replacement parts W415-4083 / 03.31.22...
  • Page 47: Troubleshooting (Millivolt - Gdi3-1)

    10.0 troubleshooting (millivolt - GDI3-1) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 48 troubleshooting (millivolt - GDI3-1) symptom problem test solution Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button ignitor. PILOT Check if the push button ignitor needs tightening. BURNER THERMOPILE Replace the wire if the wire insulation is broken or frayed.
  • Page 49: Troubleshooting (Electronic Gdi3E-1/Gdig3-1/Gdix3-1)

    11.0 troubleshooting (electronic GDI3E-1/GDIG3-1/GDIX3-1) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 50 troubleshooting (electronic GDI3E-1/GDIG3-1/GDIX3-1) symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight. Verify noise with no spark at connections connections from pilot assembly are tight;...
  • Page 51 troubleshooting (electronic GDI3E-1/GDIG3-1/GDIX3-1) symptom problem test solution Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position. equipped). COM switch is unplugged. Verify “COM” switch is plugged into the front of the control module.
  • Page 52: Warranty

    Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi...
  • Page 53 notes W415-4083 / 03.31.22...
  • Page 54 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, The Netherlands Phone: 1-866-820-8686 napoleon.com...

Table of Contents