Napoleon GDI-30GN Installation And Operating Instructions Manual

Napoleon GDI-30GN Installation And Operating Instructions Manual

Propane & natural gas, vented gas fireplace heaters

Advertisement

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
GDI-30GN

NATURAL GAS

GDI-30GP
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleon.on.ca
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1.2
W415-0832 / 09.18.09
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GDI-30GN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Napoleon GDI-30GN

  • Page 1: Natural Gas

    CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS. GDI-30GN NATURAL GAS GDI-30GP PROPANE CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION CARE OF GLASS INSTALLATION INSERT LEVELLING CHIMNEY CONNECTION GAS INSTALLATION OPTIONAL WALL SWITCH / THERMOSTAT FRAMING MINIMUM MANTEL CLEARANCES FINISHING 4 SIDED SURROUND DOOR REMOVAL AND INSTALLATION DOOR GLASS REPLACEMENT MEDIA TRAY INSTALLATION MEDIA INSTALLATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Door, see “FINISHING - DOOR REMOVAL AND INSTALLATION” section. Venting, see “INSTALLATION - CHIMNEY CONNECTION” section. Surround, see “FINISHING - 4 SIDED SURROUND INSTALLATION” section. Glass, see “FINISHING - GLASS BURNER INSTALLATION” section. W415-0832 / 09.18.09...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury. •...
  • Page 5: Dimensions

    DIMENSIONS 3” Ø COLLARS 27 ½” ” ” 25 ½” ” ” ” ” 13 ¾” ” 13 ¾” ” ” 7 ¼” RATING PLATE LOCATED 42” UNDER VALVE ACCESS DOOR GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 6: General Information

    The installation must conform with local codes or, in We suggest that our gas absence of local codes, the National Gas and Propane hearth products be installed Installation Code CSA B149.1 in Canada, or the National and serviced by professionals Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.
  • Page 7: Rating Plate Information

    REFERENCE # W/N 16479 SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. GDI-30GN / CDI-30GN GDI-30GP / CDI-30GP MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 10 FEET AND 40 FEET RESPECTIVELY. LES MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 8 FEET AND 40 FEET RESPECTIVELY. LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 10 PIEDS ET 40 PIEDS RESPECTIVEMENT.
  • Page 8: Installation

    3.0 INSTALLATION WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF USING CO-AXIL VENTING WITH SPACERS, THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 9: Chimney Connection

    CHIMNEY CONNECTION Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 2" or 3" diameter liner for intake and one 3" diameter liner for exhaust. The minimum and maximum vent lengths are 10 and 35 feet respectively. Recommended Napoleon kits come in 3 lengths: 1-2"...
  • Page 10: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 11: Framing

    4.0 FRAMING WARNING MINIMUM CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED OR A SERIOUS FIRE HAZARD COULD RESULT. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. This insert must be recessed into a vented noncombustible wood-burning appliance (prefabricated or masonry) only. The minimum appliance opening size in which the appliance is to be installed is: HEIGHT 21.75"...
  • Page 12: Finishing

    5.0 FINISHING WARNING ENSURE THE UNIT IS COMPLETELY COOL BEFORE STARTING INSTALLATION. 4 SIDED SURROUND LIGHT SWITCH ON/OFF SWITCH 5.1.1 Connect the two black on/off switch wires (al- SHOULDER ready connected to the frame) to SCREWS the white and green wires located on the lower right hand side of the appliance control compartment.
  • Page 13: Door Glass Replacement

    DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 14: Media Tray Installation

    MEDIA TRAY INSTALLATION Secure the media tray to the burner us- ing 6 screws (W570-0001). When removing the media tray make sure the glass media are away from the center of the screen, exposing the burner, remove screws and lift media tray out.
  • Page 15: Lamp Replacement

    LAMP REPLACEMENT This appliance comes equipped with our “Night Light™”. If in the event the lamp needs to be replaced, follow these instructions. 5.6.1 Turn off all electrical supply. 5.6.2 Remove the glass media and media tray from the fi rebox, see "MEDIA TRAY INSTALLATION"...
  • Page 16: Replacement Blower Installation

    6.0 REPLACEMENT BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 17: Operation

    7.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 18: Anti Condensation Switch

    ANTI CONDENSATION SWITCH This appliance has the option to go from an electronic intermittent pilot ignition (IPI) to a standing pilot for cold climates. The anti condensation control switch (standing pilot) is located on the left of the control panel. Using your fi...
  • Page 19: Night Light Tm Wiring Diagram

    NIGHT LIGHT WIRING DIAGRAM W415-0832 / 09.18.09...
  • Page 20: Adjustments

    9.0 ADJUSTMENTS PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
  • Page 21: Flame Adjustment

    FLAME ADJUSTMENT FLAME ADJUSTMENT KNOB Turn counter- Turn clockwise clockwise to to increase fl ame decrease fl ame height height FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustra- tions provided.
  • Page 22: Replacements

    11.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 23 ACCESSORIES REF NO. APPLIANCE DESCRIPTION ON / OFF REMOTE THERMOSTAT REMOTE GD-660 REMOTE WALL SWITCH WITH 20" WIRE W660-0026 TIMER, BATTERY OPERATED GI-RB RISER BOX - PAINTED BLACK W175-0322 CONVERSION KIT - LP-NG W175-0323 CONVERSION KIT - NG-LP W415-0832 / 09.18.09...
  • Page 24: Trouble Shooting

    12.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 25 SYMPTOM PROBLEM TEST SOLUTION Carbon is being Air shutter has become Ensure air shutter opening is free of lint or other deposited on blocked. obstructions. glass, logs, Flame is impinging on the Check that the glass, logs, rocks or media are rocks, media glass, logs, rocks, media correctly positioned.
  • Page 26 SYMPTOM PROBLEM TEST SOLUTION White / grey fi lm Sulphur from fuel is being Clean the glass with a recommended gas appliance forms. deposited on glass, logs or glass cleaner. DO NOT CLEAN GLASS WHEN combustion chamber HOT. surfaces. If deposits are not cleaned off regularly, the glass may become permanently marked.
  • Page 27: Warranty

    13.0 WARRANTY NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station.
  • Page 28: Service History

    14.0 SERVICE HISTORY 43.1 W415-0832 / 09.18.09...

This manual is also suitable for: