NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
GDI3NEA
GDI3PEA
INSTALLATION MANUAL
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
ADD MANUAL TITLE
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
CSA 2.33 AND ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
Oakville™ Series
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
PLACE BARCODE LABEL ON THE
IF SEPARATE MANUALS, ADD "PLACE
OWNER'S MANUAL
ENGLISH
FRENCH PG. 37
(GDI3EA illustrated)
W415-4001 / B / 06.15.22

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Oakville Series

  • Page 1 OWNER’S MANUAL BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-4001 / B / 06.15.22...
  • Page 2 safety information WARNING DANGER • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 patterns. RAAK HET GLAS NIET AAN TOT HET IS AFGEKOELD. DUTCH safety information LAAT KINDEREN NOOIT HET GLAS AANRAKEN. WARNING Dit apparaat is voorzien van een barrière die is ontworpen om het risico van brandwonden door het hete kijkglas te beperken. Deze barrière moet worden geïnstalleerd ter bescherming van kinderen •...
  • Page 4: Table Of Contents

    table of contents general information maintenance rates and efficiencies annual maintenance rating plate information care of glass shut-off valve care of plated parts dimensions door glass replacement minimum clearance to combustibles 8 restricting vertical vents installation planning valve train replacement replacement parts levelling the appliance chimney connection...
  • Page 5 standard checklist Installer: please fill out appliance checklist in the owner’s manual. 1.0 general information When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
  • Page 6 general information WARNING • Always light the pilot whether for the first time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. • Provide adequate ventilation. •...
  • Page 7: General Information

    Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 8: Dimensions

    general information dimensions front view right side view 20 15 20 1 " " SAFETY BARRIER 16" 531mm 521mm 406mm " 23 5 " 191mm 601mm 17 7 " 454mm 3" 2 PLS 18 5 " 14 5 " 15 3 "...
  • Page 9 2.0 installation planning installation planning WARNING • Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance. Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualifi ed person before installing the insert.
  • Page 10: Installation Planning

    installation planning chimney connection Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and maximum vent lengths are 10' (3m) and 45' (14m) respectively.
  • Page 11: Gas Installation

    installation planning We recommend the following method of sealing off the damper area around the liner: Measure the throat of the appliance and mark this shape on a piece of 24 gauge sheet metal (flue cover). Cut a 6 3/4" (171mm) hole to lie directly below the appliance flue opening. Allow 2" of material for a flange on all sides and cut to these measurements.
  • Page 12 3.0 finishing finishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 13: Finishing

    finishing safety barrier & door removal / installation WARNING • Glass may be hot. Do not touch glass until cooled. • If equipped with door latches that are part of a safety system, they must be properly engaged. Do not operate the appliance with latches disengaged.
  • Page 14: Log Placement

    PHAZER™ log and glowing embers, exclusive to Wolf Steel Ltd., provide a unique and realistic glowing effect “PHAZER™ logs [and glowing embers], exclusive to Napoleon/Continental, provide a unique and realistic that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing glowing effect that is different in every installation.
  • Page 15 Burner Overview finishing Lower Media Tray Lower Media Tray (Logs #6, #7, and #8) (Logs #6, #7, and #8) Pilot Shield Notch Pilot Shield Notch Lower Media Tray Lower Media Tray (Logs #6, #7, and #8) (Logs #6, #7, and #8) Pilot Shield Notch Pilot Shield Notch Pilot Shield Notch...
  • Page 16: Decorative Panels

    Notch Notch PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. finishing Notches Notches Notches Notches Place log #7 along the centre of the lower Place log #8 along the right side of the lower PLACE TEXT BOX HERE.
  • Page 17: Logo Placement

    finishing logo placement 1/2"(12.7mm) INSERT Remove the backing of the logo supplied and place, as illustrated. LOGO IMAGE 1/2"(12.7mm) HERE 45.5 glowing embers WARNING • Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition.
  • Page 18: Bracket Installation For Optional F45/60

    finishing bracket installation for optional F45/60 receiver 1. Remove the safety barrier and glass door (see "safety barrier & door removal / installation" section). 2. Remove the 1 screw holding the bracket in place (Fig. 3-5). Lift the bracket up and out of the slots, lifting it through the opening between the firebox and the appliance's outer shell (Fig.
  • Page 19: Electrical Information

    4.0 electrical information wiring diagram WARNING • Do not wire 110 volts to the valve or wall switch. ILOT SSEMBLY GNITION W010-3037 (NG) W010-3040 (P) ODULE W190-0135 3/16” ILOT ROUND ÉLECTRODE VEILLEUSE 1/4” 3/8” - 1/2” (9,5mm - 12,7mm) LA SONDE ATTERY DE FLAMME MAIN...
  • Page 20: Operation

    5.0 operation WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 21: Adjustments

    upper 3/8" to 1/2" (12.7mm - 9.5mm) of 6.0 adjustments thermocouple pilot burner adjustment Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. SIT ELECTRONIC IGNITION Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- 3/8”...
  • Page 22: Flame Characteristics

    adjustments flame characteristics It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustration provided. If any flames appear abnormal, call a service person. GDI3EA W415-4001 / B / 06.15.22...
  • Page 23: Maintenance

    7.0 maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person.
  • Page 24: Annual Maintenance

    maintenance annual maintenance WARNING • Annual maintenance should be performed by a qualifi ed service technician • The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service. • Never vacuum hot embers. •...
  • Page 25: Care Of Plated Parts

    maintenance care of plated parts If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi rst time. Use an ammonia-free or vinegar-based cleaner and a towel to clean.
  • Page 26: Restricting Vertical Vents

    maintenance restricting vertical vents Your appliance comes with restrictor plate fully closed. If carboning becomes an issue, adjust the restrictor plate by loosening the four screws and pulling the plate forwards or backwards (Fig. 7-1). Re-tighten the screws. Restrictor Plate Screws Fig.
  • Page 27: Valve Train Replacement

    maintenance valve train replacement Fig. 7-2 Remove safety barrier and glass door (see "safety barrier & door removal / installation" section). Remove media tray (see "media tray installation" section) and burners. Remove porcelain radiant panels (PRPs) or brick panels (if applicable). Remove the 14 screws holding the valve train in place (Fig.
  • Page 28: Replacement Parts

    8.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 29 replacement parts W415-4001 / B / 06.15.22...
  • Page 30 replacement parts W415-4001 / B / 06.15.22...
  • Page 31 replacement parts W415-4001 / B / 06.15.22...
  • Page 32: Troubleshooting

    troubleshooting WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. • Appliance may be hot.
  • Page 33 Check that venting is installed correctly. appliances). Room is in negative pressure; increase fresh air supply. troubleshooting symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight.
  • Page 34 Wire connector pins are bent. Straighten pins. Valve wiring is damaged. Replace valve. troubleshooting symptom problem test solution Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position. equipped).
  • Page 35: Warranty

    Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 36 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, The Netherlands Phone: 1-866-820-8686 napoleon.com...
  • Page 37 LE MANUEL DU PROPRIÉTAIRE LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com W415-4001 / A / 06.15.22...
  • Page 38 NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot consignés de sécurité viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk AVERTISSEMENT individuals.
  • Page 39 continue de s’éteindre, faire réparer. Garder propres le brûleur et le compartiment de contrôle. • Cet appareil ne devra être modifi é en aucun cas. • Ne laissez pas les ventilateurs souffl er directement sur l’appareil. Empêchez les courants d’air de modifi er consignés de sécurité...
  • Page 40 table de matières information générales entretien taux et efficacités entretien annuel information à propos de la plaque soins de la vitre d'homologation soins des pièces plaquées soupape de fermeture remplacement de la vitre de porte dimensions renstreignants d'évents verticaux dégagements minimaux aux matériaux remplacement de l'assemblage de la combustibles soupape...
  • Page 41 liste de vérification Installateur, veuillez remplir la liste de contrôle de l'appareil dans le manuel du propriétaire. 1.0 information générales Lorsque l'appareil est installé à une altitude de plus de 4 500 pieds (1382m) et en l'absence de recommendations particulières de l'autorité compétente locale, l'indice certifié du débit à haute altitude devra être réduit au taux de 4% pour chaque 1 000 pi (305m) supplémentaire.
  • Page 42 information générales AVERTISSEMENT • Allumez toujours la veilleuse, qu ce soit pour la première fois ou lorsque l'approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffisant pour entretenir et opérer l'appareil. • Assurez-vous d'une quantitée suffisante d'air de ventilation.
  • Page 43: Information Générales

    Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 44: Dimensions

    information générales dimensions vue de face vue de côté droit 20 15 20 1 " " BARRIÈRE DE 16" PROTECTION 531mm 521mm 406mm " 23 5 " 191mm 601mm 17 7 " 454mm 3" 2 PLS 18 5 " 14 5 "...
  • Page 45 2.0 planification de l'installation installation planning AVERTISSEMENT • Risque d’incendie! Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. Retirez les cendres de l’appareil de chauffage au bois. Assurez-vous que la cheminée et l’appareil de chauffage au bois sont propres et en bon état et qu’ils sont construits avec des matériaux incombustibles. Si nécessaire, faites faire les travaux de réparation par une personne qualifi ée avant d’installer l’encastré.
  • Page 46: Planification De L'installation

    planification de l'installation installation de la cheminée L’installation de la cheminée doit être conforme aux normes des codes nationaux et locaux. La cheminée doit être munie d'un conduit de 2" (51mm) ou 3" (76mm) de diamètre pour la prise d'air et d'un conduit de 3" (76mm) de diamètre pour l'évacuation.
  • Page 47: Branchement Du Gaz

    planification de l'installation note: Avant de fixer l'appareil en place, isolation à haute température devrait être emballé autour du linéaire dans la zone du registre pour empêcher le flux d'air d'entrer dans la cheminée de la maison. Ne pas le faire aura un impact négatif sur l'efficacité...
  • Page 48 3.0 finitions finishing AVERTISSEMENT • Risque d’incendie! • N’obstruez jamais l’ouverture sur le devant de l’appareil. • La façade de l’appareil doit être faite de matériaux incombustibles comme de la brique, du marbre, du granite, etc., à condition que ces matériaux ne se trouvent pas en deçà de la dimension spécifi ée tel qu’illustré. Comme alternative, vous pouvez utiliser le panneau de gypse comme fi nition pour votre appareil, voir les illustrations à...
  • Page 49: Enlèvement Et Installation De La Barrière

    finitions enlèvement et installation de la barrière de protection et la porte AVERTISSEMENT • La vitre peut être chaude. Ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. • Si équipé avec les loquets de porte qui font partie d’un dispositif de sécurité, ils doivent être adéquatement verrouillés.
  • Page 50: Disposition Des Bûches

    finitions disposition des bûches AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet apareil peut causer des dommages matériels ou des blessures corporelles. • Les bûches doivent être placées correctement à l’intérieur de l’appareil. Ne changez pas la position des bûches car l’appareil risque de ne pas fonctionner adéquatement et un retard d’allumage risque de se produire.
  • Page 51 Burner Overview (Bûche #6, #7, et #8) (Bûche #6, #7, et #8) finitions Plateau à Média Plateau à Média Inférieur Inférieur Encoche de l’Écran de Veilleuse Encoche de l’Écran de Veilleuse (Bûche #6, #7, et #8) (Bûche #6, #7, et #8) Plateau à...
  • Page 52: Panneaux Décoratifs

    NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. Encoches Encoches finitions Encoches Encoches Placez la bûche #7 sur le centre de la plateau à Placez la bûche #8 sur le côté droite de la PLACE TEXT BOX HERE. PLACE TEXT BOX HERE.
  • Page 53: Mise En Place Du Logo

    finitions mise en place du logo 1/2"(12.7mm) INSERT Retirez le papier dorsal du logo et placez-le sur comme illustrée. LOGO IMAGE 1/2"(12.7mm) HERE 45.5 braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage.
  • Page 54: Installation De Support Pour Récepteur Optionnel F45/60

    finitions installation de support pour récepteur optionnel F45/60 1. Retirez la barrière de protection et la porte vitrée (voir la section « enlèvement et installation de la barrière de protection et la porte »). 2. Retirez la 1 vis servant à fixer le support en place (Fig. 3-5). Soulevez le support et sortez-le des fentes, en le soulevant à...
  • Page 55: Information Électrique

    4.0 information électrique schéma de câblage AVERTISSEMENT • Ne raccordez pas l’interrupteur mural ou la soupape de gaz à l’alimentation électrique (110 V). ASSEMBLAGE PILOTE W010-3037 (GN) W010-3040 (P) MODULE D’ALLUMAGE W190-0135 3/16” LIGNE DE IL DE ÉLECTRODE GAZ PILOTE VEILLEUSE ERRE 1/4”...
  • Page 56: Fonctionnement

    5.0 fonctionnement AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Si applicable, allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 57: Réglages

    Flame must envelop La flamme doit envelopper upper la thermocouple de 3/8" à 3/8" to 1/2" 1/2" 6.0 réglages (12.7mm - 9.5mm) of (9.5mm - 12.7mm) thermocouple réglage de la veilleuse Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz.
  • Page 58: Caractéristiques De La Flamme

    réglages caractéristiques de la flamme Il est important d'effectuer périodiquement une inspection visuelle de la flamme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des flammes paraissent anormales, contactez un techicien de service. GDI3EA W415-4001 / A / 06.15.22...
  • Page 59: Entretien

    7.0 entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation devraient être inspectés avant la première utilisation et au moins une fois l’an par un technicien de service qualifi é.
  • Page 60: Entretien Annuel

    entretien entretien annuel AVERTISSEMENT • Le caisson devient trés chaud lors du fonctionnement. Laissez l’appareil se refroidir complétement ou portez des gants antichaleur avant d’effectuer l’entretien. • Ne jamais aspirer des braises qui sont chaudes. • Ne peinturez pas l’assemblage de la veilleuse. •...
  • Page 61: Soins Des Pièces Plaquées

    entretien soins des pièces plaquées Si l’appareil est muni de pièces plaquées, vous devez enlever toutes traces de doigts ou autres marques des surfaces plaquées avant d’allumer l’appareil pour la première fois. Utilisez les nettoyants sans ammoniaque ou à base de vinaigre. Si la surface plaquée n’est pas bien nettoyée avant le premier allumage de l’appareil, elle risque de rester marquée en permanence.
  • Page 62: Renstreignants D'évents Verticaux

    entretien renstreignants d'évents verticaux Votre appareil est livré avec une plaque de restriction complètement fermée. Si l'émission de carbon devient un problème, ajustez la plaque de restriction en desserrant les quatre vis et tirant la plaque vers l'avant et vers l'arrière (Fig.
  • Page 63: Remplacement De L'assemblage De La Soupape

    entretien remplacement de l'assemblage de la soupape Fig. 7-2 Retirez la barrière de protection et porte vitrée (voir la section « enlèvement et installation de la barrière de protection et la porte »). Retirez la plateau média (voir la section « installation de plateau média ») et brûleurs. Enlevez les panneaux réflecteurs radiants (PRPs) ou les panneaux simibriques (si l'applicable).
  • Page 64: Pièces De Rechange

    8.0 pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 65 pièces de rechange W415-4001 / A / 06.15.22...
  • Page 66 pièces de rechange W415-4001 / A / 06.15.22...
  • Page 67 pièces de rechange W415-4001 / A / 06.15.22...
  • Page 68: Guide De Dépannage

    guide de dépannage AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 69 guide de dépannage symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi ez l’interrupteur de bloc n’est pas endommagée ou trop serré.
  • Page 70 Câble défecteux. Remplacer. fi ls sont courbeés. Les piles du récepteur ou Remplacez les piles. Le télécommande ne La télécommande s’allume mais Réinitiliser en tourant l’alimentation « off » puis « on ». Câblage de la soupape est Remplacez la soupape. télécommmande sont faibles.
  • Page 71: Garantie

    10.0 garantie Les produtits Napoléon sont fabriqués conformément aux normes strictes du Système de Gestion de la Qualité mondialement reconnu ISO 9001 : 2015. Les produits Napoléon sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi és qui sont fi ers de leur travail.
  • Page 72 NAPOLÉON CÉLÈBRE PLUS DE 40 ANS D’EXISTENCE CONSACRÉS À LA CONCEPTION DE PRODUITS DE CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, Pays-Bas Téléphone: 1-866-820-8686...