Napoleon GDIZC-P Installation And Operation Instructions Manual
Napoleon GDIZC-P Installation And Operation Instructions Manual

Napoleon GDIZC-P Installation And Operation Instructions Manual

Gas-fired direct vent insert, vented gas fireplace heater

Advertisement

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
INSTALLATION AND OPERATION INSTRUCTIONS FOR:
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service
R-2000
GAS-FIRED DIRECT VENT INSERT
VENTED GAS FIREPLACE HEATER
NATURAL GAS MODELS
PROPANE GAS MODELS
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
FOR YOUR SAFETY
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
agency or the gas supplier.
GDIZC - N
GDIZC - P
• Immediately call your gas supplier
from a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
1
W415-0223 / D / 01.12.04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GDIZC-P and is the answer not in the manual?

Questions and answers

Summary of Contents for Napoleon GDIZC-P

  • Page 1 CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS GAS-FIRED DIRECT VENT INSERT INSTALLATION AND OPERATION INSTRUCTIONS FOR: VENTED GAS FIREPLACE HEATER NATURAL GAS MODELS PROPANE GAS MODELS CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 2: Table Of Contents

    NOTE: changes, other than editorial, are denoted by a vertical line in the margin. W415-0223 / D / 01.12.04 Pg 9 OPERATION / MAINTENANCE Operating Instructions Maintenance REPLACEMENT BLOWER ADJUSTMENTS Pilot Burner Adjustment Vent Restrictions Venturi Adjustments 12-13 REPLACEMENTS Ordering Replacement Parts Replacement Parts Terminal Kits Accessories...
  • Page 3: Conditions And Limitations

    NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 4: General Instructions

    Purge all gas lines with the glass door of the fireplace insert opened. Assure that a continuous gas flow is at the burner before closing the door. Under extreme vent configurations, allow several min- utes (5-15) for the flame to stabilize after ignition.
  • Page 5: Installation

    Provide adequate ventilation air. Provide adequate accessibility clearance for servicing and operating the fireplace insert. Never obstruct the front opening of the fire- place insert. Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
  • Page 6: Insert Vent Connection

    INSERT VENT CONNECTION Move the insert close to its final position inside the wood- burning fireplace. This unit is equipped with 6 levelling screws located as follows: two are on either side of the circulation blower on the rear panel; four are located front and back on either side beneath the log support.
  • Page 7: Wall Switch / Thermostat

    WALL SWITCH / THERMOSTAT For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt ther- mostat.
  • Page 8: Log Placement

    GLOWING EMBERS 4. Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs will glow.
  • Page 9: Operation / Maintenance

    11. If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner. 12. Turn on all electric power to the fireplace.
  • Page 10: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION FIGURE 21 1. Turn off the electrical power and the gas supply to the fireplace insert. 2. Remove the fire viewing door. Remove the logs. FIGURE 22 3. Detach the two screws from the back of the firebox and remove the panel, as illustrated.
  • Page 11: Adjustments

    Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be estab- lished.
  • Page 12: Replacements

    REPLACEMENT PARTS W725-0039 RBT SHAW VALVE - NG W725-0040 RBT SHAW VALVE - LP W100-0068 BURNER W455-0017 #42 BURNER ORIFICE - NG W455-0059 #53 BURNER ORIFICE - LP W010-0800 PILOT ASSEMBLY - LP W010-0801 PILOT ASSEMBLY - NG W455-0069 PILOT INJECTOR - NG...
  • Page 13 W415-0223 / D / 01.12.04 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 14: Trouble Shooting Guide

    Faulty thermostat or switch W415-0223 / D / 01.12.04 PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor.
  • Page 15 SYMPTOM PROBLEM REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON" Main burner goes out; pilot goes out. Vent re-circulating Thermocouple shorting or faulty. Vent is reversing Exhaust fumes Fireplace is spilling. smelled room, headaches. Carbon is being de- Air shutter has become...
  • Page 16 W415-0223 / D / 01.12.04...

This manual is also suitable for:

Gdizc-n

Table of Contents