Operating Instructions Caravan-charging system CSV 416
Battery
Generator operation and
passenger vehicle
ferries
Operation with solar
regulator
Operation on towing
vehicle
4
3.1
Starting up the caravan charging system
ATTENTION!
Y
An incorrect setting on the caravan charging system will result in damage to
the battery connected. Ensure therefore that, prior to start-up, the battery
selector switch (Fig. 4, Pos. 10) is in the correct position for the battery
installed.
ATTENTION!
Y
The caravan charging system, 12V consumers and connected devices can
be damaged if the thresholds for the 230V supply are exceeded. So there-
fore:
Do not connect a generator until it is running smoothly.
F
It is essential that the generator conforms to the specifications of the
F
mains supply.
Do not connect the caravan charging system to the onboard mains
F
voltage on car ferries (non-problematic mains voltage cannot always
be guaranteed on car ferries).
The use of an upstream overvoltage protection device is recommen-
ded.
ATTENTION!
Y
When connecting a solar regulator, note that the buffer function of the bat-
tery is an absolute requirement, i.e. the battery must be connected before a
solar regulator is connected.
ATTENTION!
Y
Switch off the ignition when the towing vehicle is parked (when the caravan
is connected to the towing vehicle). Otherwise the starter battery of the
towing vehicle might discharge.