Technical Details; Mechanical Details; Electrical Details - Schaudt CSV 416 Operating Instructions Manual

Caravan-charging system
Table of Contents

Advertisement

Operating Instructions Caravan-charging system CSV 416
Dimensions
Weight
Casing
Base plate
Mains connection
Current consumption
Suitable batteries
Standby current from
Caravan battery
Current-carrying
capacity
Battery charging
caravan battery
connected to mains
14
6

Technical details

6.1

Mechanical details

320 x 217 x 111 (W x D x H in mm), including attachment feet
2.0 kg
PA (polyamide), gentian blue (RAL 5010)
Aluminium, bare
6.2

Electrical details

230 V AC voltage 10 %, 47-63Hz sinewave, protection class I
Approx. 3.2 A at full load
Approx. 3.0 W in idle
Lead-acid, lead-gel, AGM (1/2) or lithium batteries from 80 Ah
18 mA (Sleep-Mode) @12,6V; plus consumption of refrigerator control
electronics
Conditions for the measurement:
approx. 10 minutes after disconnection from the mains
F
12.6V battery voltage
F
All consumers switched off
F
12 V main switch OFF
F
12 V outputs
rent
D+ output
Charge curve
End of charge voltage between 14.3 V and 14.8 V
Charge current
Voltage for float charge
New charge cycle,
Switchover to main charge
U
charge
V
U
VL
U
EL
U
R
Fig. 5
Example of the charging voltage curve with the CSV 416 power supply
A maximum of 90% of the nominal cur-
of the relevant fuse may be
drawn.
Approx. 2.5 A
IUoU (in 5 phases)
28 A in the entire mains voltage range,
limited electronically
between 13.2 V and 13.8 V (depending on
battery type), with automatic
switchover
with battery voltage below 13.2 V
and 13.8 V (depending on battery type)
with a couple of seconds delay
t
t
t
VL
EL
R
Date: 30.05.2021
t
F
t
8050111 BA / EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents