Schaudt CSV 416 Operating Instructions Manual
Schaudt CSV 416 Operating Instructions Manual

Schaudt CSV 416 Operating Instructions Manual

Caravan-charging system

Advertisement

E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de
8050111 BA
Operating Instructions
Caravan-charging system CSV 416

Table of contents

1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2.1
2.2
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1
3.2
3.3
4
4.1
4.2
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1
5.2
5.3
6
6.1
6.2
6.3
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
30.05.2021
2
2
2
2
3
4
5
5
7
8
10
11
12
13
13
14
14
14
15
15
16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSV 416 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schaudt CSV 416

  • Page 1: Table Of Contents

    ..........E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de 8050111 BA 30.05.2021...
  • Page 2: Introduction

    Operating Instructions Caravan-charging system CSV 416 Introduction This instruction manual contains important information for the safe operation of equipment supplied by Schaudt. Make sure you read and follow the safety instructions provided. The operating instructions should always be kept in the vehicle. All safety information must be passed on to other users.
  • Page 3: Operation

    Operating Instructions Caravan-charging system CSV 416 Never try to start the device using a defective mains cable or a faulty connection. Never undertake maintenance on the device when it is live. DANGER! Incorrect installation Electric shock or damage to connected devices: Install as shown in installation instructions.
  • Page 4: Starting Up Caravan Charging System

    Operating Instructions Caravan-charging system CSV 416 Starting up the caravan charging system Battery ATTENTION! An incorrect setting on the caravan charging system will result in damage to the battery connected. Ensure therefore that, prior to start-up, the battery selector switch (Fig. 4, Pos. 10) is in the correct position for the battery installed.
  • Page 5: Switching On And Off

    Operating Instructions Caravan-charging system CSV 416 Switching on and off Control and switch panels must be supplied with a separate operating ma- nual (kept with the vehicle). Please refer to this manual for instructions on operation. Activating the 12V main switch (12V ON) on the operating panel connected enables/disables the following electrical circuits: Pos.
  • Page 6 Operating Instructions Caravan-charging system CSV 416 Proceed as follows for a battery change: Changing Disconnect the battery from the caravan charging system by switching " the battery the main 12 V switch off. Disconnect the caravan charging system from the 230 V supply.
  • Page 7: Application And Function

    Fig. 2 On-board power supply system The CSV 416 caravan charging system is the central power supply unit for all 12 V consumers connected to the caravan’s electrical system. It is usually located in a cupboard or storage area and is accessible from the front in order to change fuses.
  • Page 8: Battery Functions

    Operating Instructions Caravan-charging system CSV 416 Actuation A bus-compatible control panel must be connected for operation. Connections provided for: Bus devices Two tank sensors Solar charge regulator (optional) Flat vehicle fuses protect the various circuits. Protective circuits Excess temperature Overload Short circuit 230V AC ...
  • Page 9 Battery monitor For systems in which the CSV 416 caravan power supply is used, another device monitors the leisure area battery voltage (such as the panel connec- ted to the LIN bus). When the voltage is too low, this device must send a control signal to the CSV 416, that disconnects all consumers from the battery (12 V OFF and switching outputs 1 to 3 OFF).
  • Page 10: Additional Functions

    ATTENTION! The CSV 416 can no longer detect a deeply discharged battery (battery is high-impedance) and so transitions to supply mode. When the battery ”reco- vers” (such as with charging when the vehicle is moving using a booster, or with solar charging), it is detected automatically again by the CSV 416 and charged.
  • Page 11: Layout

    Appendix E). Layout 11 12 13 14 16 17 Fig. 4 Front view of CSV 416 A caravan charging system Connector for water tap Connector for trailer coupling plug 10 Connector for refrigerator controller Connector for caravan battery Connectors for switching outputs 1, 2, 3 and D+ Connector for solar charge regulator LR ...
  • Page 12: Operating Faults

    If this is not possible, e.g. if you are abroad, you can have the caravan charging system repaired at a specialist workshop. In this case, you must ensure that the warranty is not invalidated by incorrect repairs being carried out. Schaudt GmbH will not accept any liability for damage resulting from such repairs. Fault...
  • Page 13: Switching Off The System

    ATTENTION! Connected consumers can be damaged on exceeding the input voltages permitted. So therefore: Do not operate any connected Schaudt LR ... solar charge regulator without battery. When the battery is replaced or removed, unplug the ”Caravan bat- tery” connector on the CSV 416A beforehand (or unplug the ”+ Solar cell”...
  • Page 14: Technical Details

    13.8 V (depending on battery type) with a couple of seconds delay charge        Fig. 5 Example of the charging voltage curve with the CSV 416 power supply Date: 30.05.2021 8050111 BA / EN...
  • Page 15: Environmental Parameters

    Operating Instructions Caravan-charging system CSV 416  I (”Bulk”) Main charge with maximum 20 A charging current, electronically limited, up to end-of-charge voltage U . Start of charge also for completely discharged batteries.  Uo (”Absorption”) Automatic switchover to full charging with constant voltage U .
  • Page 16: Appendix

    Address Planckstraße 8 88677 Markdorf Germany Special fittings/accessories Solar- Schaudt solar charger LR ... model for solar modules with a total current of charge 14A, including 0.5 m connection cable and connector plug regulator Customer service Customer Schaudt GmbH, Elektrotechnik & Apparatebau service Planckstraße 8...
  • Page 17 Operating Instructions Caravan-charging system CSV 416 Fault report In the event of damage, please fill in the fault report and send it with the faulty device to the manufacturer. Device type: _______________________ Part no.: _______________________ Vehicle: Manufacturer: _______________________ Model: _______________________...
  • Page 18 Operating Instructions Caravan-charging system CSV 416 Block diagram/wiring diagram * AHK assignment of the towing vehicle / caravan connector as per EN 1648-1. Connectors AHK 9 and AHK 10 must be fused CSV 416 ST external within the vehicle (max. 15A).