RS-232 Connector Pin-Out
The OneLINK device passes signals from a third-party device to the connected camera.
OneLINK Receiver - RS-232 Control Port
Pin
Signal
1
(not used)
2
(not used)
3
(not used)
4
(not used)
5
(not used)
6
GND
7
RX (from TX of controller)
8
TX (to RX of controller)
Mounting the OneLINK Device
Rack and under-table mounting kits are available for the receiver. Follow the mounting instructions
supplied with the kit.
About Installations Using Half-Recessed Ceiling Mounts
If the connected camera is mounted in an In-CEILING Half-Recessed Ceiling Mount for RoboSHOT
series cameras, and the mount's IR receiver will be used to forward commands to the camera, this must
be powered separately using Power Extension Module 998-2225-051. Cameras powered by OneLINK
devices cannot supply power to the mount's IR receiver.