Accessing The Web Interface Manually; If The Device Is At 169.254.10.1 - LEGRAND VADDIO OneLINK Bridge Express Manual

Av interface
Table of Contents

Advertisement

To complete the initial device set-up with the Vaddio Deployment Tool:
1. Download and install the Vaddio Deployment Tool if you have not done so already, then open it.
2. Power up the OneLINK device if you have not done so already.
3. On the Find Devices page, click Scan. If the scan does not locate the device, your computer may be
on a different subnet. Click Advanced and specify the appropriate portion of the network to scan.
4. In the list of equipment that the scan discovers, locate the devices marked Not Set Up.
5. For each device that you need to work with, click the Not Set Up button and set the admin password
on the device detail page that opens. Other people using the Vaddio Deployment Tool then have the
option to log in, as shown for the other devices in the screen shot.
You can use the Vaddio Deployment Tool to access the web interface of any device in the device list, if it
is set up and you have provided the admin password.
If the Vaddio Deployment Tool cannot discover the OneLINK device, you may need to
interface
manually.

Accessing the Web Interface Manually

To get the IP address:
Press the button labeled Display IP and MAC Address, on the front of the unit. The information is overlaid
on the video outputs.
The OneLINK device uses the default address of 169.254.10.1 if no DHCP server is available. In this
situation, you will need to connect a computer to the OneLINK device's network port and configure
network settings.
To access the web interface:
Enter the IP address in your browser's address bar. You may need to enter https:// as a prefix to keep
the browser from treating it as a search query.
After the device is set up, you can access its web interface by its hostname instead of its IP address.

If the Device Is At 169.254.10.1

This is the device's default IP address. This means one of these things:
n
The device is not connected to the network – check the cable connected to the Network port.
The network does not automatically assign IP addresses, and you need to configure the device for
n
the network.
To communicate directly with the device:
Connect a cable from your computer's network port to the device's network port. You do not need to
disconnect other devices.
After completing the initial device set-up, you will need to configure the device with a static IP address.
Work with your network administrator.