Operation; Start-Up; Operating Thermostat; EliwellId971 - Viessmann norpe SPIRIT User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
SM
The electrical connections for the cabinet are shown in the wiring diagram in the plastic wallet
attached to the side of the electrical terminal box. Always replace the wiring diagram after use.
For more information on the location of the rating plates and wiring diagrams, see figure pages
1-5 in the beginning of this manual.
WARNING
All electrical connections must be carried out by approved and qualified personnel and
comply with all IEE and local regulations, failure to do this could result in personal or
fatal injury.

3. Operation

3.1. Start-up

Display cabinets are designed for remote installation. The company that installs the
cabinet/refrigeration equipment must provide adequate training and instructions on the operation
and location of power supply and service switches needed when carrying out normal cleaning.
The expansion valves in the cabinets must be set to the correct value before starting up the
cabinets. The set values for the thermostats in the cabinets should be checked with a separate
and accurate thermometer.
NOTE
For cabinets with an integrated machinery unit, the cooling equipment - compressor,
condenser and electrical equipment - is located in the machinery compartment on the
right-hand side of the cabinet as viewed from the service side. The cooling equipment
starts when the electrical plug is inserted into the wall socket.

3.2. Operating thermostat

The interior temperatures of the cabinets are controlled by thermostats. During the cooling phase,
the thermostat opens the magnetic valve in the coolant line.
NOTE
For cabinets with an integrated machinery unit, the thermostat (see figure page 3, figures
B1-E1) switches on the compressor in the machinery compartment.
The operating thermostat of the cabinet is set when the cabinet is started up. The setting takes
into account both the temperature required by the products to be displayed and the operating
temperature of the cabinet. Setting the thermostat to a lower temperature may freeze and stop
the evaporator.
The temperature in the cabinet should be checked at regular intervals.
The operating thermostat is set with factory settings. For the operating thermostat instructions,
see the thermostat's own user manual. In case of problems, contact your service company.
3.2.1. Eliwell ID 971
Eliwell ID 971 is a cabinet controller that automates cabinet defrosting by
means of a thermostat and temperature sensor.
3.2.1.1. Keys and menus
The instrument is programmed and controlled with four keys:
Version05/2015
ENGLISH
9

Advertisement

Table of Contents
loading