1.2 LCD Monitor PMLCD-BTJ (PM300-BTJ only)
The LCD monitor is a digital control center for the PM335J transformer unit. See section 5.2 for operation of LCD monitor.
FEATURES:
• T-Bus design (can be connected to multiple devices)
• System monitoring
• Configuration
• Built-in Bluetooth for pairing to smart phone
1.3 Water Tank Probes
A maximum of up to 4 probes can be monitored by the system.
NOTE: Always check the probe required for the water tank before purchase.
There are 2 probe styles:
PMWS200:
• Side installation
• Suitable for water tank
• Depth >200mm
PMWS400:
• Side installation
• Suitable for water tank
• Depth 300-400mm
2. KEY FEATURES AND
FUNCTIONS
2.1 Multiple Inputs
The PM335J transformer unit accepts inputs from AC mains,
solar panel and vehicle battery. However, see Table 1 at right for
details.
2.2 Battery Charger Of House Battery
The charger automatically starts when the appropriate qualified power is connected, either from AC mains, alternator or solar.
With multiple charging stages (soft start-bulk absorption float-recycle), PM335J is designed to fully charge a battery quickly.
To guarantee the optimal charging for batteries of different states, the PM335J features a Microprocessor-controlled charging
algorithm. The Float and Recycle charging programs guarantees that the battery condition does not change despite being
connected for a longer period.
6
Figure 3 Overview of Monitor
Figure 4 PMWS200
Figure 5 PMWS400
AC MAINS
SOLAR
VEHICLE
BATTERY
DOMINATING
SOURCE
Table 1 Multiple inputs
x
x
x
x
AC MAINS
AC MAINS
x
x
COMBINE