Display; Pm335J Transformer Unit - Projecta IntelliJay PM300-BTJ Instruction Manual

12v power management system mppt
Table of Contents

Advertisement

5. DISPLAY

5.1 PM335J Transformer Unit

No.
LED
COLOUR
1
Mains
GREEN
2
Vehicle Bat
GREEN
3
Solar
GREEN
4
CHG
GREEN
5
FAULT
RED
Table 7 LED indicator description of PM335J
P/No. PM335
Figure 22 An overview of PM335J
STATUS
ON
OFF
Quick flashing (flash twice every second)
ON
Slow flashing (flash once every second)
Quick flashing (flash twice every second)
OFF
ON
Slow flashing (flash once every second)
Quick flashing (flash twice every second)
OFF
ON
Slow flashing (flash once every second)
Quick flashing (flash twice every second)
OFF
ON
Flash once per cycle
Flash twice per cycle
Flash 3 times per cycle
Flash 4 times per cycle
Flash 5 times per cycle
Flash 6 times per cycle
DESCRIPTION
AC input OK
AC disconnected
AC input abnormal
Alternator charging the house battery
Vehicle battery is >13.4V and is being charged by
the AC
The vehicle battery is 2~13.4V or >16.0V, while
AC power is connected.
Vehicle battery is disconnected.
Solar charging the battery
The input voltage of the Solar is normal but it is
charged by the AC or vehicle battery
Solar input voltage error – Solar voltage >50VDC
Solar disconnected
Battery charged
Battery charging
Battery discharge
Battery disconnected
Short circuit
House battery voltage low
House battery voltage high
PM335J unit Over Temperature
Bulk charge timeout
VCR anomaly
Environment Over Temperature
15