6.5 MAINTENANCE

6.5.1 Battery SOC Monitoring
The PM335J transformer unit features built-in state of charge (SOC) monitoring for the house battery. To ensure accurate display of this
information on the LCD monitor and in the app, the following conditions must be adhered to:
1. Battery capacity is set correctly in the LCD or app – refer to your battery specifications.
2. When replacing a battery, ensure it is fully charged via AC mains for the first time.
3. Fully charge battery via AC mains at least once every 3 months, until the 'CHG' LED light on the PM335J transformer unit remains on
(solid) or 'float' shows on the monitor.

6.5.2 DAILY MAINTENANCE

• Ensure the Power Switch on the transformer unit is ON when you want to charge the battery with AC mains.
• Check the nominal battery voltage is 12VDC.
• Ensure there is space (5cm each side) beside the PM335J unit for the appropriate ventilation.

7. TROUBLE SHOOTING

7.1 L.E.D Display on PM335J Transformer Unit
No.
LED
COLOUR
1
Mains
Green
2
Vehicle Bat Green
3
Solar
Green
4
Fuse LED
Red
5
Fault
Red
Table 17 Error LED indicator of PM335J

7.2 Error Code on LCD Monitor

ERROR
DESCRIPTION
CODE
8001
Lose communication
8003
Loss of communication
8004
Battery voltage high
8005
Solar voltage low
8006
Solar voltage high
8010
Battery temperature high
8011
Battery temperature low
8012
Internal temperature high
8013
Vehicle battery voltage low
Table 18 Error Code List
STATUS
Quick flashing
(flash twice every second)
Quick flashing
(flash twice every second)
Quick flashing
(flash twice every second)
Solid
ON
Flash once per cycle
Flash twice per cycle
Flash 3 times per cycle
Flash 4 times per cycle
Flash 5 times per cycle
Flash 6 times per cycle
ERROR
CODE
8014
8015
8016
8017
8018
8027
8028
8030
8031
DESCRIPTION
AC input abnormal
The vehicle battery is 2~13.4V or >16.0V, while
AC power is connected.
Solar input voltage error – Solar Input >50VDC
Fuse blown, need to check load and replace fuse
Short circuit
House battery voltage low
House battery voltage high
PM335J unit over temp
Bulk charge timeout
VCR anomaly
Environment over temp
DESCRIPTION
Vehicle battery voltage high
Over load
Output short circuit
Module protection
Battery maintenance notice
VCR connect is error
VCR disconnect error
Environment temperature is high
Bulk stage time-out
21