• BALANCE: Changes left/right balance. (For more information on Balance
sections.)
NOTE: This setting is stored permanently even after the RC-1590 is
powered off.
• DIMMER: Dims the display.
NOTE: This setting is stored permanently even after the RC-1590 is
powered off.
• ROTEL LINK RCD: Selects how the CD player is connected to the amplifier,
either CD (analog), COAX1, COAX2 and BAL-XLR. CD is the factory default.
• POWER ON MAX VOLUME: This sets the maximum volume level when
the unit is turned ON. "45" is the factory default.
NOTE: Power On Max Volume settings do not apply to sources
configured with Fixed Gain.
• POWER OPTION: Enables the RC-1590 to be controlled via the network
port when attached to an automation system. The power consumption is
higher in Quick Power mode. If network control is not required select the
Normal Power mode. "Normal" is the factory default.
Valid settings include: Normal, Quick.
NOTE: When the POWER OPTION is configured to Quick, the RC-
1590 will consume additional power in standby mode.
NOTE: Some regions limit the amount of Standby Power Consumption
allowed and the POWER OPTION function will not be available. To
control the Rotel product in this case use the RS232 connection. For
questions on the availablity of the Power Option please contact your
authorized Rotel dealer.
• AUTO POWER OFF: The RC-1590 can be configured to automatically
power off if unused for a specified period. If no changes are made to the
unit within the specified "Auto Power Off" timer the unit will automatically
go to STANDBY mode. The Auto Power Off timer will be restarted if
changes are made to the volume, source or playback. The default for
Auto Power Off is set to DISABLE.
Valid settings include: DISABLE, 1 HOUR, 2 HOURS, 5 HOURS, 12 HOURS.
NOTE: Some regions require the AUTOMATIC POWER OFF timer
default setting to be 20 minutes. This can be changed in the SETUP
MENU to any of the available options. For questions about the Automatic
Power Off settings please contact your authorized Rotel dealer.
NOTE: Some products cannot detect ANALOG signal inputs and
the unit may power off if there is no digital audio source detected or
user action with the remote control or front panel. Analog input signal
detection is not available in all models which may cause the unit to
inadvertently power off. In this case the Automatic Power Off timer
should be set to DISABLED.
• FIXED GAIN: Configures a Fixed Volume level for a specified input. To
enable this feature press the +/- buttons on the front panel to select the
desired fixed volume level for Aux, FUSB, PC-USB, Coax 1, Coax 2,
Optical 1, Optical 2 or Bluetooth. When enabled and the input with a
Fixed Volume is selected, the Volume level will immediately be set to the
specified level.
Valid settings include: VARIABLE, FIXED 01-95, FIXED MAX.
• AUX VOL: VARIABLE (disabled) is factory default.
• FUSB VOL: VARIABLE (disabled) is factory default.
• PC-USB VOL: VARIABLE (disabled) is factory default.
• OPT1 VOL: VARIABLE (disabled) is factory default.
• OPT2 VOL: VARIABLE (disabled) is factory default.
• COAX1 VOL: VARIABLE (disabled) is factory default.
• COAX2 VOL: VARIABLE (disabled) is factory default.
• BLUETOOTH VOL: VARIABLE (disabled) is factory default.
NOTE: The Volume knob on the front panel and Volume +/- buttons
on the IR remote are disabled when the volume is Fixed. To disable this
feature set the Fixed Volume level to "Variable".
• PC-USB AUDIO CLASS: Changes supported PC-USB Audio Class of the
attached device.
NOTE: Some computers attached to the PC-USB do not support USB
Audio Class 2.0 and do not support 32/ 384 audio playback. If needed
the PC-USB can be configured for USB Audio Class 1.0. Please consult
your computer operating system for details.
• NETWORK: Shows the network connection status and to view/configure
the network settings. If the network is properly configured and attached
"Connected" will be displayed. To view or modify the network settings
press the ENTER button.
The RC-1590 supports both DHCP and STATIC IP addressing. Select the
desired IP address method and press ENTER.
If DHCP is selected you can refresh IP address by pressing ENTER or press
MENU to view IP address information. Press the MENU button to toggle
through IP address settings. If the IP address is renewed the network will
be tested and connection status reported.
If STATIC IP address mode is selected you must configure all settings for the
network including IP Address, Subnet Mask, Gateway and DNS Server. Use
the left/right or +/- buttons to adjust the values and press ENTER to move to
the next value. When the proper IP information is configured press MENU
to go to the next setting. After entering the STATIC IP address information
the network will be tested and connection status reported.
NOTE: For more information regarding network connection please
contact your authorized Rotel dealer.
NOTE: A network connection is not required for the RC-1590 to
operate.