NetVanta 340 Series Hardware Installation Guide

Factory Default Switch

If pressed during bootup, the default switch will cause the unit to stay in bootstrap mode. Since the unit
has no serial port, Telnet has been built into the boot code. The default IP address is 10.10.10.1.
The default switch must be pressed WHILE the power light is flashing green. Do not press
the default switch BEFORE the power light is flashing green, as this will cause boot to be
missed.
If pressed and held for 5 seconds after boot, the
access policies will be removed from that interface.
If pressed for 30 seconds, a default configuration will overwrite your existing configuration and reboot
the unit.
Maximum recommended ambient operating temperature is 50
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.