ACDI
Setting the Minimum Vend
The ACD3000 series has a feature called the minimum vend. This is the
smallest amount that must be entered to enable the copier or mfp. By having
this setting independent from the price lines, the ACD3000 series can force a
patron to deposit enough money to cover all vend options on copiers that do not
give advanced signaling for color, duplex, and paper size options.
You can adjust the minimum vend by following the steps below:
Enter Supervisor Pin – 73784230
1.
Press ENTER display will read "Service Mode"
2.
Press ENTER display will read "Meters Menu"
3.
Press FWD until display reads "Price Menu"
4.
Press ENTER, then display will read "Edit Prices Cash Customers"
5.
Press FWD until display reads "Edit Prices Minimum Vend"
6.
Press ENTER, then display will read "Minimum Vend Price $0.00".
7.
8.
Press ENTER to Edit Price (cursor will appear on the display)
9.
Using the keypad enter the new price and press ENTER to save.
10. Press EXIT 2 times followed by EJECT to exit the Service Mode.
Features
Membrane Switch/Overlay
The ACD3000 series features a membrane switch keypad built in to the
graphic overlay. This keypad provides access to all menus and options as
well as supervisor pin accounts and user pin accounts. There are several
different options and models available. The LCD is a 2 line, 16-character
display with a backlight allowing for multiple lines of text and instructions
to be displayed.
RS232 Serial Interface
With the addition of a RS232 serial interface, the ACD3000 series has expanded
areas of use and has eased the hassle of upgrades and service. This standard 9-
pin serial connector allows the ACD3000 to interface with software applications
as well as ACDI's Bootloader program. The Bootloader program allows users
to reload the software on to the unit.