Installation instruction
Location Requirements
NOTES:
•
The flexible exhaust hose allows placement of the air
conditioner between 23 1/2" and 67" (60 cm and 170 cm) from
window or door.
The appliance with supplementary heater needs to keep a
minimum distance of 100 cm from the combustible surfaces.
The appliance shall be installed,operated and stored in a room
which floor area larger than 11 m² and higher than 2.2 m.
Local air conditioners are designed as supplemental cooling
to local areas within a room.
•
To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least
23 1/2" (60 cm).
•
Do not block air outlet.
•
Provide easy access to grounded outlet.
•
The universal WPRO branded "Window Kit" are available
online and are compatible with any window and sliding doors
in aluminun, wood and PVC.
Electrical Requirements
•
The local air conditioner should be connected to a
220-240V / 50Hz, 20-amp fused grounded outlet.
•
The use of a time-delay fuse or time-delay circuit breaker is
recommended.
•
All wiring must comply with local and national electrical
regulations and be installed by a qualified electrician.
If you have any questions, contact a qualified electrician.
Use your power supply cord:
Plug power supply cord into a grounded outlet.
The Flexible Exhaust Hose should be connected in both cooling
mode operation.
NOTES:
•
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
•
Working temperature of Cooling 21°C- 35°C
Vertical
Silde Window
combustible surfaces
100 cm
Horizontal
Silde Window
combustible surfaces
100 cm
-18-
60 cm - 170 cm
60 cm - 170 cm