Installation instruction

Location Requirements
NOTES:
The flexible exhaust hose allows placement of the air
conditioner between 23 1/2" and 67" (60 cm and 170 cm) from
window or door.
The appliance with supplementary heater needs to keep a
minimum distance of 100 cm from the combustible surfaces.
The appliance shall be installed,operated and stored in a room
which floor area larger than 11 m² and higher than 2.2 m.
Local air conditioners are designed as supplemental cooling
to local areas within a room.
To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least
23 1/2" (60 cm).
Do not block air outlet.
Provide easy access to grounded outlet.
The universal WPRO branded "Window Kit" are available
online and are compatible with any window and sliding doors
in aluminun, wood and PVC.
Electrical Requirements
The local air conditioner should be connected to a
220-240V / 50Hz, 20-amp fused grounded outlet.
The use of a time-delay fuse or time-delay circuit breaker is
recommended.
All wiring must comply with local and national electrical
regulations and be installed by a qualified electrician.
If you have any questions, contact a qualified electrician.
Use your power supply cord:
Plug power supply cord into a grounded outlet.
The Flexible Exhaust Hose should be connected in both cooling
mode operation.
NOTES:
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
Working temperature of Cooling 21°C- 35°C
Vertical
Silde Window
combustible surfaces
100 cm
Horizontal
Silde Window
combustible surfaces
100 cm
-18-
60 cm - 170 cm
60 cm - 170 cm