SKIRT REPLACEMENT

Bristle Skirt Removal
1. Remove the Bulb Housing from the UVGI Frame Assembly (see Bulb Housing Assembly Removal and Installation).
2. Remove the 7 Screws (4) that secure the Plastic Cover (5) to the Bulb Housing (6).
3. Remove the 12 Screws (7) that secure the Bristle Skirts (8) to the Plastic Cover (5).
4. Installation is the reverse of removal.
6
4
Inner Rubber Skirt Removal
1. Remove the Bulb Housing from the UVGI Frame Assembly (see Bulb Housing Assembly Removal and Installation).
2. Remove the 7 Screws (4) that secure the Plastic Cover (5) to the Bulb Housing (6).
3. Remove the 27 Screws (10) that secure the Mounting Straps (11) which hold the Inner Rubber Skirts (12) to the Bulb Housing
(6).
4. Installation is the reverse of removal.
5. Reinstall the Bulb Housing onto the UVGI Frame Assembly (see Bulb Housing Assembly Removal and Installation).