Device
SuperBus 2000 energy saver module
SuperBus 2000 automation module
SuperBus 2000 wireless cellular gateway
Interrogator 200
Interrogator AVM
Two-wire smoke detectors (ESL 429AT,
429C, 429CT, 521B, 521BXT, 521NCSXT
Two-wire smoke detectors (system sensor
2400, 2400TH)
Hardwired interior siren (13-949)
Piezo dynamic exterior siren (13-950)
Speaker siren (60-528 or 13-060)
*Maximum current draw for the SnapCards does not include the load which may be applied to
their auxiliary DC supply.
Table 5 below describes the total system wire lengths allowed for all SuperBus
2000 devices when installing systems using unshielded or shielded cable. After
determining panel location, run all necessary wires to that location using the
information in Table 6 on page 10.
Table 5: Wire lengths
Wire type
18-gauge, unshielded
18-gauge, shielded
Concord 4 Installation Manual
Max. wire
Standby mA
length to
draw
panel
22 ga.: 1,600
20 mA
ft.
18 ga.: 4,000
ft.
22 ga.: 1,500
30 mA
ft.
18 ga.: 4,000
ft.
22 ga.: 40 ft.
65 mA
18 ga.: 90 ft.
22 ga.: 3,200
10 mA
ft.
18 ga.: 4,500
ft.
22 ga.: 110 ft.
45 mA
18 ga.: 260 ft.
22 ga.: 330 ft.
70 µA
18 ga.: 330 ft.
22 ga.: 330 ft.
120 µA
18 ga.: 330 ft.
22 ga.: 750 ft.
0 mA
18 ga.: 1,500
ft.
22 ga.: 750 ft.
0 mA
18 ga.: 1,500
ft.
18 ga.: 100 ft.
0 mA
Total system wire
4,000 ft.
3,000 ft.
Chapter 2: Installation
Alarm mA draw
20 mA
35 mA
1600 mA
10 mA
300 mA
60 mA
80 mA
85 mA
150 mA
500 mA