Operating mode 'Automatic'
Operating mode 'Sound control'
Operating mode 'Slave'
Automatic operation can only be activated when the unit is operating in stand alone mode or
as master in a master / slave combination. This setting is only relevant if the device is not con‐
trolled via DMX.
Press [Mode] repeatedly until the display shows 'AUTO' . The playback of the automatic show
starts automatically.
The sound controlled automatic show can only be activated when the unit is operating in
stand alone mode or as master in a master / slave combination. This setting is only relevant if
the device is not controlled via DMX.
Press [Mode] repeatedly until the display shows 'Soud' . This activates the sound controlled
automatic show.
Press [Setup] and use [Up] and [Down] to adjust the sensitivity for the sound control in a range
from 'SU.00' to 'SU.31' .
This setting is only relevant if the device is serving as Slave in a Master / Slave configuration
and is not controlled via DMX.
Press [Mode] repeatedly until the display shows 'SLAv' .