required bypass, see DirectFax Document 1059, available only to authorized dealers though the
technical resources listed at the front of this guide.
Primary Harness (H1),Wire Connection Guide
Primary Harness (H1) Wiring Diagram
___
ORANGE
H1/1
___
___
___
___
___
___
___
___
H1/9
OPEN
___
___
___
Primary Harness Wire Descriptions
H1/1 ORANGE (-) Ground-When-Armed Output
This wire supplies a (-) 500 mA ground as long as the system is armed. This output ceases as soon
as the system is disarmed. The orange wire is pre-wired to control the 8618 starter kill relay.
NOTE: If using the H1/1 ORANGE wire to activate an add-on accessory such as window
automation, pager or voice module a 1 Amp diode must be installed to ensure proper operation.
Insert the diode as shown in the following diagram.
IMPORTANT! Never interrupt any wire other than the starter wire.
©
2003
Directed Electronics, Inc.
(-) 500 mA Armed Output
(+)/(-) Selectable Light Flash Output
(-) Remote Start Activation Input
(-) 200 mA Domelight Supervision Output
(-) Door Trigger Input, Zone 3
(-) Multiplexed Input, Zone 4
(+) Door Trigger Input, Zone 3
(-) Chassis Ground Input
(+) Siren Output
(+) Constant Power Input
(-) 200 mA Channel 2 Output
No Wire
7