Summary of Contents for Lincoln Electric POWERTEC i450C ADVANCED

  • Page 1 IM3171 04/2022 REV01 ® POWERTEC i450C ADVANCED OPERATOR’S MANUAL ENGLISH Lincoln Electric Bester Sp. z o.o. ul. Jana III Sobieskiego 19A, 58-260 Bielawa, Poland www.lincolnelectric.eu...
  • Page 2: Table Of Contents

    12/05 THANK YOU! For choosing the QUALITY of the Lincoln Electric products.  Please check packaging and equipment for damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For ease of use, please enter your product identification data in the table below. Model Name, Code & Serial Number can be found on the machine rating plate.
  • Page 3: Technical Specifications

    Technical Specifications NAME INDEX POWERTEC ® i450C ADVANCED K14376-1 INPUT Input Voltage U EMC Class Frequency i450C ADVANCED 400V ± 15%, 3-phase 50/60Hz Input Power at Rated Cycle Input Amperes I 1max 20,3 kVA @ 80% Duty Cycle i450C ADVANCED 29 A 0,94 (40°C)
  • Page 4: Eco Design Information

    ECO design information The equipment has been designed in order to be compliant with the Directive 2009/125/EC and the Regulation 2019/1784/EU. Efficiency and idle power consumption: Efficiency when max power Index Name Equivalent model consumption / Idle power consumption ® POWERTEC i450C K14376-1...
  • Page 5 Typical gas usage for MIG/MAG equipment: DC electrode positive Wire Wire Feeding Gas flow Material type diameter Shielding Gas Current Voltage [m/min] [l/min] [mm] Carbon, low 0,9 ÷ 1,1 95 ÷ 200 18 ÷ 22 3,5 – 6,5 Ar 75%, CO alloy steel Aluminium 0,8 ÷...
  • Page 6: Electromagnetic Compatibility (Emc)

    If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances, if necessary with assistance from Lincoln Electric. WARNING Provided that the public low voltage system impedance at the point of common coupling is lower than: ...
  • Page 7: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or equipment damage. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 8 WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION: Remove fire hazards from the welding area and have a fire extinguisher easily accessible. Welding sparks and hot materials from the welding process can easily go through small cracks and openings to adjacent areas. Do not weld on any tanks, drums, containers, or material until the proper steps have been taken to insure that no flammable or toxic vapors will be present.
  • Page 9: Introduction

    Introduction General Description The complete package contains:  Work lead – 3m, The welding machines POWERTEC ® i450C ADVANCED  Gas hose – 2m, enables welding:  Driving roll V1.0/V1.2 for solid wire (mounted in the  GMAW (MIG/MAG), wire feeder). ...
  • Page 10 Rear Panel Output Connections Refer to points [2], [3] and [4] of the Figures below. Controls and Operational Features Front panel Figure 2 10. Wire Liner Entry: Enables installing liner for welding wire delivered in drum package. 11. Top Chain: To protect gas bottle. Figure 1 12.
  • Page 11 Internal Controls User Interface Advanced (U7) Figure 3 21. Spooled Wire (for GMAW / FCAW): Not supplied as standard. Figure 4 22. Wire Spool Holder: Maximum 16kg spools. Holder Detailed operation of User Interface U7 can be found in allows mounting plastic, steel and fiber spools onto the Advanced (U7) IM3170 user manual.
  • Page 12 For non-synergic mode can set: Welding GMAW and FCAW Process in  Wire Feed Speed, WFS non-synergic mode  The welding voltage During non-synergic mode wire feed speed and welding  Burnback Time voltage are independent parameters and must be set by ...
  • Page 13 Welding SMAW Process Loading the Electrode Wire ® POWERTEC i450C ADVANCED does not include the Depending on the type of wire spool it can be installed on electrode holder with lead necessary for SMAW welding, the wire spool support without adapter or installed with but the one can be purchased separately (see use applicable adapter that must be purchased separately "Accessories"...
  • Page 14 Adjusting of Pressure Roll Force Changing Driving Rolls The pressure arm controls the amount of force the drive rolls exert on the wire. Pressure force is adjusted by WARNING turning the adjustment nut clockwise to increase force, Turn the input power off before installation or changing counterclockwise to decrease force.
  • Page 15 Gas Connection Transport & Lifting WARNING WARNING  Falling equipment can cause injury and CYLINDER may explode if damaged.  damage to unit. Always fix the gas cylinder securely in an upright position, against a cylinder wall rack or purpose-made cylinder cart. ...
  • Page 16 We respond to our customers based on the best be lost. information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, Any noticeable damage should be reported immediately and assumes no liability, with respect to such information and repaired.
  • Page 17: Weee

    12/05 Part List reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
  • Page 18: Accessories

    Accessories K14201-1 CABLE MANAGEMENT KIT K14325-1 DISPLAY COVER KIT LE K14328-1 BUMPERS K10095-1-15M REMOTE CONTROL K2909-1 6-PIN/12-PIN ADAPTER K14290-1 12PIN REMOTE HARNESS KIT K14175-1 GAS FLOW METER KIT K14176-1 GAS HEATER KIT K14182-1 COOLER COOLARC 26 R-1019-125-1/08R ADAPTER FOR SPOOL S200 K10158-1 ADAPTER FOR SPOOL TYPE B300 K10158...